Programming (continued) WIRING TYPE DEVICE ACTION STATE Operator at OPEN limit Operator at CLOSE limit OPEN Door opening button is pressed Door closing momentarily Door at Open Mid-Stop Door stopped during open or close cycle T Momentary contact to open, close, and stop, with Operator at OPEN limit CLOSE button is Operator at CLOSE limit Door opening pressed Door closing momentarily Door at Open Mid-Stop open override and Timer-ToClose (TTC). Every device that causes the door to open, except any sensing edge Door stopped during open or close cycle Front panel Operator at OPEN limit buttons Operator at CLOSE limit (membrane) and 3-Button Wall STOP button is pressed momentarily Door opening Door closing Controller Door at Open Mid-Stop Door stopped during open or close cycle input device, Operator at OPEN limit activates the TTC. Auxiliary controls can be connected to open input to activate the TTC. If the TTC has OPEN button is held (constant pressure) Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop been activated, the open button and radio control can recycle the timer. The stop button will deactivate the timer until the next command input. The TTC CLOSE button is held (constant pressure) Door stopped during open or close cycle Operator at OPEN limit Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit will function from the Open limit stop and Open Mid-Stop available with this mode type. Operator at CLOSE limit OPEN button is Door opening pressed Door closing momentarily Door at Open Mid-Stop Compatible with 3-Button Station, 1-Button Station and 1 and 3-Button Remote Control. Close Mid-Stop is available but 3-Button Remote Control Programmed as OPEN/ CLOSE/ STOP CLOSE button is pressed momentarily Door stopped during open or close cycle Operator at OPEN limit Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop not shown in Door stopped during open or close cycle table. Operator at OPEN limit Monitored Entrapment Protection (LMEP) Device required. Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit Single Button Remote Control Programmed Button is pressed as SBC Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during the open cycle Door stopped during the close cycle RESPONSE No change in state (Recycle timer) Door opens to the OPEN limit or Mid-Stop (and activates TTC) No change in state Door will auto reverse to OPEN limit or Mid-Stop (and activates TTC) Door opens to the OPEN limit (and activates TTC) Door opens to the OPEN limit or Mid-Stop (and activates TTC) Door closes to the CLOSE limit No change in state No change in state No change in state Door closes to the CLOSE limit Door closes to the CLOSE limit No change in state (Deactivate timer) No change in state Door stops Door stops No change in state (Deactivate timer) No change in state No change in state (Recycle & hold timer) Door opens to the OPEN limit (bypasses MidStop) and activates TTC No change in state (bypasses Mid-Stop) Door will auto reverse to OPEN limit (bypasses Mid-Stop) and activates TTC Door opens to the OPEN limit and activates TTC Door opens to the OPEN limit (bypasses MidStop) and activates TTC Door closes to the CLOSE limit No change in state No change in state No change in state Door closes to the CLOSE limit Door closes to the CLOSE limit No change in state (Recycle timer) Door opens to the OPEN limit or Mid-Stop and activates TTC No change in state Door will auto reverse to OPEN limit or Mid-Stop and activates TTC Door opens to the OPEN limit and activates TTC Door opens to the OPEN limit or Mid-Stop and activates TTC Door closes to the CLOSE limit No change in state No change in state No change in state Door closes to the CLOSE limit Door closes to the CLOSE limit No change in state (Deactivate timer) No change in state Door stops Door stops No change in state (Deactivate timer) No change in state Door closes to the CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC Door stops Door will auto reverse to OPEN limit or Mid-Stop and activates TTC Door opens to the OPEN limit and activates TTC Door closes to the CLOSE limit Door opens to the OPEN limit or Mid-Stop and activates TTC 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

39
Programming (continued)
WIRING
TYPE
DEVICE
ACTION
STATE
RESPONSE
T
-
Momentary
contact to
open, close,
and stop, with
open override
and Timer-To-
Close (TTC).
Every device
that causes the
door to open,
except any
sensing edge
input device,
activates the
TTC. Auxiliary
controls can be
connected to
open input to
activate the TTC.
If the TTC has
been activated,
the open button
and radio control
can recycle
the timer. The
stop button will
deactivate the
timer until the
next command
input. The TTC
will function
from the Open
limit stop and
Open Mid-Stop
available with
this mode type.
Compatible
with 3-Button
Station, 1-Button
Station and 1
and 3-Button
Remote Control.
Close Mid-Stop
is available but
not shown in
table.
Monitored
Entrapment
Protection
(LMEP) Device
required.
Front panel
buttons
(membrane)
and 3-Button
Wall
Controller
OPEN
button is
pressed
momentarily
Operator at OPEN limit
No change in state (Recycle timer)
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop (and
activates TTC)
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
(and activates TTC)
Door at Open Mid-Stop
Door opens to the OPEN limit (and activates
TTC)
Door stopped during open or close cycle
Door opens to the OPEN limit or Mid-Stop (and
activates TTC)
CLOSE
button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button
is pressed
momentarily
Operator at OPEN limit
No change in state (Deactivate timer)
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state (Deactivate timer)
Door stopped during open or close cycle
No change in state
OPEN
button
is held
(constant
pressure)
Operator at OPEN limit
No change in state (Recycle & hold timer)
Operator at CLOSE limit
Door opens to the OPEN limit (bypasses Mid-
Stop) and activates TTC
Door opening
No change in state (bypasses Mid-Stop)
Door closing
Door will auto reverse to OPEN limit (bypasses
Mid-Stop) and activates TTC
Door at Open Mid-Stop
Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle
Door opens to the OPEN limit (bypasses Mid-
Stop) and activates TTC
CLOSE
button
is held
(constant
pressure)
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
3-Button
Remote
Control
Programmed
as OPEN/
CLOSE/
STOP
OPEN
button is
pressed
momentarily
Operator at OPEN limit
No change in state (Recycle timer)
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop and
activates TTC
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door at Open Mid-Stop
Door opens to the OPEN limit and activates TTC
Door stopped during open or close cycle
Door opens to the OPEN limit or Mid-Stop and
activates TTC
CLOSE
button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button
is pressed
momentarily
Operator at OPEN limit
No change in state (Deactivate timer)
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state (Deactivate timer)
Door stopped during open or close cycle
No change in state
Single Button
Remote
Control
Programmed
as SBC
Button is
pressed
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop and
activates TTC
Door opening
Door stops
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
and activates TTC
Door at Open Mid-Stop
Door opens to the OPEN limit and activates TTC
Door stopped during the open cycle
Door closes to the CLOSE limit
Door stopped during the close cycle
Door opens to the OPEN limit or Mid-Stop and
activates TTC