LiftMaster TDC Installation Manual - English French Spanish - Page 34

Set Operating Mode, WIRING, ACTION, STATE, RESPONSE

Page 34 highlights

Programming (continued) Determine and Set Operating Mode Select the operating mode for your application from the menu in the Wall Controller. WIRING TYPE DEVICE ACTION STATE RESPONSE Operator at OPEN limit No change in state Operator at CLOSE limit OPEN button is pressed momentarily Door opening Door closing Door at Open Mid-Stop Door opens to the OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop Operator at OPEN limit Door closes to the CLOSE limit CLOSE Operator at CLOSE limit button is Door opening pressed Door closing momentarily Door at Open Mid-Stop No change in state No change in state No change in state Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Operator at OPEN limit No change in state B2 Momentary contact to open,close Front panel buttons (membrane) and 3-Button Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door stops Door stops No change in state and stop, plus Wall Door stopped during open or close cycle No change in state wiring for Controller Operator at OPEN limit No change in state sensing device to reverse and auxiliary devices to open and close with open override. Programmable Mid-Stops available with this wiring type. Close Mid Stop available but not shown in table. Operator at CLOSE limit OPEN button is held Door opening (constant Door closing pressure) Door at Open Mid-Stop Door opens to the OPEN limit (bypasses MidStop) No change in state (bypasses Mid-Stop) Door will auto reverse to OPEN limit (bypasses Mid-Stop) Door opens to the OPEN limit Door stopped during open or close cycle Door opens to the OPEN limit (bypasses MidStop) CLOSE button is held (constant pressure) Operator at OPEN limit Door closes to the CLOSE limit Operator at CLOSE limit No change in state Door opening No change in state Door closing No change in state Door at Open Mid-Stop Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Operator at OPEN limit Operator at CLOSE limit OPEN button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door opens to closest OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Remote Door stopped during open or close cycle Door opens to the OPEN limit Control. Monitored Entrapment 3-Button Remote Control CLOSE button is Operator at OPEN limit Operator at CLOSE limit Door opening Door closes to the CLOSE limit No change in state No change in state Protection Programmed pressed Door closing No change in state (LMEP) Device required. as OPEN/ CLOSE/STOP momentarily Door at Open Mid-Stop Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Operator at OPEN limit No change in state Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door stops Door stops No change in state Door stopped during open or close cycle No change in state Operator at OPEN limit Door closes to the CLOSE limit Single Button Remote Control Programmed as SBC Button is pressed Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during the open cycle Door opens to the OPEN limit or Mid-Stop Door stops Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door closes to the CLOSE limit Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

34
Programming (continued)
Determine and Set Operating Mode
Select the operating mode for your application from the menu in the Wall Controller.
WIRING
TYPE
DEVICE
ACTION
STATE
RESPONSE
B2
-
Momentary
contact to
open,close
and stop, plus
wiring for
sensing device
to reverse
and auxiliary
devices to
open and
close with
open override.
Programmable
Mid-Stops
available with
this wiring
type. Close Mid
Stop available
but not shown
in table.
Compatible
with 3-Button
Station,
1-Button
Station, 1
and 3-Button
Remote
Control.
Monitored
Entrapment
Protection
(LMEP) Device
required.
Front panel
buttons
(membrane)
and 3-Button
Wall
Controller
OPEN button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit or Mid-Stop
CLOSE
button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
OPEN button
is held
(constant
pressure)
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit (bypasses Mid-
Stop)
Door opening
No change in state (bypasses Mid-Stop)
Door closing
Door will auto reverse to OPEN limit (bypasses
Mid-Stop)
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit (bypasses Mid-
Stop)
CLOSE
button
is held
(constant
pressure)
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
3-Button
Remote
Control
Programmed
as OPEN/
CLOSE/STOP
OPEN button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or close cycle
Door opens to the OPEN limit
CLOSE
button is
pressed
momentarily
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
Door closes to the CLOSE limit
Door stopped during open or close cycle
Door closes to the CLOSE limit
STOP button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or close cycle
No change in state
Single Button
Remote
Control
Programmed
as SBC
Button is
pressed
Operator at OPEN limit
Door closes to the CLOSE limit
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
Door stops
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during the open cycle
Door closes to the CLOSE limit
Door stopped during the close cycle
Door opens to the OPEN limit or Mid-Stop