Xerox C2424 Service Manual - Page 123
Xerox C2424 - WorkCentre Color Solid Ink Manual
UPC - 095205676532
View all Xerox C2424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
13,328.43: The CYAN heater is too hot. 13,330.45: The CYAN heater took too long to reach its setpoint. 13,387.48: The CYAN thermistor circuit is open. 13,389.41: The CYAN thermistor circuit is shorted. 13,391.43: The CYAN thermistor returned a bad reading, or was corrupted by ESD. 13,392.44: The MAGENTA heater is too hot. 13,394.46: The MAGENTA heater took too long to reach its setpoint. 13,451.49: The MAGENTA thermistor circuit is open. 13,453.42: The MAGENTA thermistor circuit is shorted. 13,455.44: The MAGENTA thermistor returned a bad reading, or ESD corruption. 13,456.45: The YELLOW heater got too hot. 13,458.47: The YELLOW heater took too long to reach its setpoint. 13,515.41: The YELLOW thermistor circuit is open. 13,517.43: The YELLOW thermistor circuit is shorted. 13,519.45: The YELLOW thermistor returned a bad reading, or ESD corruption. 13,520.46: The BLACK heater got too hot. 13,522.48: The BLACK heater took too long to reach its setpoint. 13,579.42: The BLACK thermistor circuit is open. 13,581.44: The BLACK thermistor circuit is shorted. 13,583.46: The BLACK thermistor returned a bad reading, or ESD corruption. Troubleshooting Procedure Step Questions and Actions Yes 1 1. Verify that the ambient temperature of the room is within the systems optimal environmental specification (see "System Environmental Specifications" on page 1-14). 2. Is the room too cold or too hot? Advise customer of specification requirements. 2 1. Ensure ground integrity of the system, (see Go to Step 3. "Ensuring Ground Integrity" on page 4-73). 2. Are all components grounded properly? 3 1. Run the appropriate Ink Melt test. 1 = Yellow 2 = Cyan 3 = Magenta 4 = Black 2. Did the test pass? Replace the electronics module. No Go to Step 2. Resolve ground integrity. Go to Step 4. Error Messages and Codes 3-31