Xerox C2424 Service Manual - Page 107
XX.4x Errors - X-Axis Fault, 6,0XX.6x Errors - Program Faults
UPC - 095205676532
View all Xerox C2424 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
6,0XX.4x Errors - X-Axis Fault 6,000.41: An X-axis motor current error occured. Troubleshooting Procedure Step Questions and Actions 1 1. Inspect the printhead power cable and heater wiring. 2. Verify the printhead travels smoothly from left to right. 3. Ensure the printhead does not bind due to ink spills. 4. Is anything visibly restricting printhead movement? 2 1. Clear the wiring or ink spill, which is restricting movement of the printhead. 2. Did this correct the problem? 3 1. Inspect the X-axis wiring harness. 2. Is the wiring damaged or faulty? 4 1. Use service diagnostics to test the X-axis drive. 2. Did the test fail? Yes Go to Step 2. No Go to Step 3. Complete. Go to Step 3. Replace the Go to Step 4. defective wiring. Replace the Xaxis motor. Replace the electronics module. 6,0XX.6x Errors - Program Faults 6,001.64: The X-axis task recieved an unexpected message. 6,002.65: Attempt to home the X-axis from a state where homing is not allowed. 6,008.62: Attempt to use the X-axis drive without initializing it. 6,011.65: Attempt to service the X-axis while not in the appropriate state. 6,013.67: Unknown X-axis program fault. 6,017.62: An attempt was made to drive the X-axis using the wrong server. 6,018.63: An attempt was made to move with the X-axis uninitialized. 6,019.64: An attempt was made to move the X-axis from a homeless state. 6,023.68: Could not allocate memory for X-axis home parameters. 6,025.66: An attempt was made to home with the X-axis uninitialized. 6,032.68: Could not find a solution to the described home motion profile. 6,033.60: Could not allocate memory for X-axis move parameters. a. Reset NVRAM, and then retest. b. Ensure ground integrity for the system (see "Ensuring Ground Integrity" on page 4-73). Error Messages and Codes 3-15