Lantronix SGX 5150 IoT Device Gateway SGX 5150 Command Reference - Page 99
email config-action-email:on scheduled reboot level commands
View all Lantronix SGX 5150 IoT Device Gateway manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
6: Commands and Levels exit Exits to the next higher level. no alarm message Removes the alarm email message. no alarm reminder interval Only one message will be sent when the alarm turns on. no normal message Removes the normal email message. no normal reminder interval Only one message will be sent when the alarm turns off. normal email email Specifies the email number to send when the alarm turns off. normal email none Specifies no email when the alarm turns off. normal message Sets the email message to be sent when the alarm turns off. normal reminder interval Sets the time interval that messages will be sent while the alarm remains off. show Shows the current configuration. show history Displays the last 20 commands entered during the current CLI session. write Stores the current configuration in permanent memory. email (config-action-email:on scheduled reboot) level commands alarm email email Specifies the email number to send when the alarm turns on. alarm email none Specifies no email when the alarm turns on. alarm message Sets the email message to be sent when the alarm turns on. alarm reminder interval Sets the time interval that messages will be sent while the alarm remains on. clrscrn Clears the screen. default alarm email Restores the default and no email is sent when the alarm turns on. default normal email Restores the default and no email is sent when the alarm turns off. exit Exits to the next higher level. no alarm message Removes the alarm email message. no alarm reminder interval Only one message will be sent when the alarm turns on. no normal message Removes the normal email message. no normal reminder interval Only one message will be sent when the alarm turns off. normal email email Specifies the email number to send when the alarm turns off. normal email none Specifies no email when the alarm turns off. normal message Sets the email message to be sent when the alarm turns off. normal reminder interval Sets the time interval that messages will be sent while the alarm remains off. show Shows the current configuration. show history Displays the last 20 commands entered during the current CLI session. write Stores the current configuration in permanent memory. email (config-action-email:eth0 link state change) level commands alarm email email Specifies the email number to send when the alarm turns on. alarm email none Specifies no email when the alarm turns on. alarm message Sets the email message to be sent when the alarm turns on. alarm reminder interval Sets the time interval that messages will be sent while the alarm remains on. clrscrn Clears the screen. default alarm email Restores the default and no email is sent when the alarm turns on. default normal email Restores the default and no email is sent when the alarm turns off. exit Exits to the next higher level. no alarm message Removes the alarm email message. no alarm reminder interval Only one message will be sent when the alarm turns on. no normal message Removes the normal email message. no normal reminder interval Only one message will be sent when the alarm turns off. normal email email Specifies the email number to send when the alarm turns off. normal email none Specifies no email when the alarm turns off. normal message Sets the email message to be sent when the alarm turns off. SGX™ 5150 IoT Device Gateway Command Reference 99