Epson ColorWorks C7500 ESC/label Command Reference Guide - Page 141
ESC/Label Command Reference Guide, Rev. E,
View all Epson ColorWorks C7500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
3. WN: Warnings WN(, ) ... All warnings can be received as . If no warning occurs, the format is WN. An ASCII character string is set as the identifier for . The 9 types shown in the following table are defined as identifiers. Identifier Warnings IC1 Cyan ink cartridge low warning IM1 Magenta ink cartridge low warning IY1 Yellow ink cartridge low warning IK1 Black ink cartridge low warning MNF Maintenance box near full warning NCR Nozzle clog recovering warning NSU Nozzle check disabled WSC Service call warning WNC Nozzle clog warning [Usage example] An example of sending and receiving data when request the remaining ink in the printer is shown below. ~H(QIQ Request to send current remaining ink. Example of response data from the printer: ->IQ, RH, RM, RL, RN - Sufficient black ink remaining status - Moderate cyan ink remaining status - Low magenta ink remaining status - Yellow ink cartridge replacement required soon status An example of the data sent and received when specifying Parameter a outside of the definition range is shown below. ~H(QAA Request to send the printer status specified with "AA" of outside the definition range. Example of response data from the printer: ->AA,#NA The printer status specified with "AA" is not defined. [Reference] Related function specifications: None Related commands: None ESC/Label Command Reference Guide Rev. E Page 141