Epson ColorWorks C7500 ESC/label Command Reference Guide - Page 125
ESC/Label Command Reference Guide, Rev. E,
View all Epson ColorWorks C7500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 125 highlights
The following figures indicate the positioning of the field when standard, 90° rotation, 180° rotation, and 270° rotation are set for the field orientation. The dotted lines show the positioning of the field when "^FO" sets the field origin location to the left side, "^FB" sets the wrapping for the field character string, and "ABCDE" was specified for the field data. (The white circle indicates the field origin.) [Normal] [90° rotation] [180° rotation] [270° rotation] AB C D E ABC DE ABC DE AB C D E When the origin coordinate is specified by "^FO" and "^FT" for each field, if the field origin location is omitted, the default field origin location set in this command is applied. Whether the field origin location is put in the left or right of the field is set using "^FO" or "^FT" based on Parameter j. When left is selected, the field origin is put in the left of the defined field. When right is selected, the field origin is put in the right of the defined field. [Response] None [Reference] Related commands: ^FO, ^FT ESC/Label Command Reference Guide Rev. E Page 125