Epson ColorWorks C7500 ESC/label Command Reference Guide - Page 110
ESC/Label Command Reference Guide, Rev. E,
View all Epson ColorWorks C7500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
^FC [Name] Set clock identifier [Format] ^FC f ,s ,t Parameters Description Range f Primary clock identifier 1 character in ASCII code s Secondary clock identifier 1 character in ASCII code t Tertiary clock identifier 1 character in ASCII code [Function] Sets the identifier used when calling the date and time of the real-time clock in the field data. To print the date and time, it must be rendered as field data for "^FD" and "^FV". After executing this command, you can acquire and print the date and time of the real-time clock in "^FD" and "^FV" in the same field. In the field data, the print format for the date and time must be specified as "identifier + letter". The following indicates the print format the user can specify. Here, indicates the identifier. Identifier + letter Format for embedding date and time Value range (English) %Y Year (4 digits) 4 digit numeral %y Year (2 digits) 00 to 99 %m Month 01 to 12 %B Month name January to December %b Month abbreviation Jan to Dec %d Date (In month) 01 to 31 %j Date (In year) 001 to 366 %w Day of the week 00 (Sunday) to 06 (Saturday) %A Name of day of the week Sunday to Saturday %a Day of the week abbreviation Sun to Sat %U Week number with Sunday as start 00 to 53 %W Week number with Monday as start 00 to 53 %H Time (24-hour clock) 00 to 23 %I Time (12-hour clock) 01 to 12 %p AM/PM AM or PM %M Min. 00 to 59 %S Sec. 00 to 59 [Response] None [Reference] Related commands: ^FD, ^FV, ^SO, ^SL ESC/Label Command Reference Guide Rev. E Page 110