Epson ColorWorks C7500 ESC/label Command Reference Guide - Page 115
ESC/Label Command Reference Guide, Rev. E,
View all Epson ColorWorks C7500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 115 highlights
^FO [Name] Field origin location [Format] ^FO x ,y ,j Parameters Description Range x x coordinate of field origin on label [dot] 0 ≤ x ≤ 32000 y y coordinate of field origin on label [dot] 0 ≤ y ≤ 32000 j Specifies field origin location j = 0/1/2 0: Left 1: Right 2: Auto [Function] Sets the field origin location relative to the home position. The field origin location is set relative to the home position based on Parameters x and y. The field origin location is set to the top right or top left of the field based on Parameter j. If left is selected, the field origin location is set to the top left of the field. If right is selected, the field origin location is set to the top right of the field. The y-direction coordinate in the bottom of the field matches with the bottom rendered edge. However, if the block height is specified based on ^TB, the specification of ^TB is followed. The x coordinate in the right or left side of the field (side farther from the origin) is determined as follows. If left is selected, the x coordinate in the right side of the field matches the farthest-right rendering edge. However, if the block width is specified based on "^TB", the specification of "^TB" is followed. If right is selected, the x coordinate in the left side of the field matches the farthest-left rendering edge. However, if the block width is specified based on "^TB", the specification of "^TB" is followed. ESC/Label Command Reference Guide Rev. E Page 115