Denon AVR-4306 Owners Manual - Page 65

Multi zone music entertainment system

Page 65 highlights

Advanced Operation Multi zone music entertainment system • When the outputs of the "ZONE2 (ZONE3)" OUT terminals are wired and connected to power amplifiers installed in other rooms, different sources can be played in rooms other than the MAIN ZONE in which this unit and the playback devices are installed. (Refer to ZONE2 (ZONE3) on the diagram below.) • Settings can be made at "Power Amp Assign" in the "System Setup Menu" so that the same source as the ZONE2 (ZONE3) preout terminals can be played from the speakers connected to the ZONE2 (ZONE3) speaker terminals ( page 76). • When a sold separately room-to-room remote control unit (DENON RC-616, 617 or 618) is wired and connected between the MAIN ZONE and ZONE2 (ZONE3), the remote-controllable devices in the MAIN ZONE can be controlled from ZONE2 (ZONE3) using the remote control unit. To control playback devices other than the ones above, either use that device's remote control unit or preset a separately sold programmable remote control unit. • For instructions on installation and operation of separately sold devices, refer to the devices' operating instructions. Multi-zone playback using the ZONE2 and ZONE3 PREOUT terminals 2 When using the power amplifier as the MAIN ZONE output • The AVR-4306 is equipped with pre-out terminals for which the volume is adjustable and video output terminals (composite and SVideo) as the ZONE2 output terminals, and variable output level as the ZONE3 output terminals. [System configuration and connections example] Using external amplifier. MAIN ZONE 7.1-channel system Monitor FL DVD player C AVR-4306 FR SW Input SL RC-616 ZONE2 AUDIO OUT (VARIABLE OUT) SR ZONE2 VIDEO OUT ZONE 2 Monitor Power Amplifer B RC-617 PROGRAMMABLE REMOTE CONTROL UNIT ZONE 3 RC-617 Power Amplifer B PROGRAMMABLE REMOTE CONTROL UNIT SB SB L R SYSTEM REMOTE CONTROL UNIT RC-1024 ZONE3 AUDIO OUT (VARIABLE OUT) : MULTI SOURCE VIDEO signal cable : MULTI SOURCE AUDIO signal cable : ROOM-TO-ROOM REMOTE CONTROL SYSTEM (separately sold) control line Refer to "Connections" ( page 22). 60 Advanced Operation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

60
Advanced Operation
Advanced Operation
• When the outputs of the “ZONE2 (ZONE3)” OUT terminals are wired and connected to power amplifiers installed in other rooms,
different sources can be played in rooms other than the MAIN ZONE in which this unit and the playback devices are installed. (Refer
to ZONE2 (ZONE3) on the diagram below.)
• Settings can be made at “Power Amp Assign” in the “System Setup Menu” so that the same source as the ZONE2 (ZONE3) pre-
out terminals can be played from the speakers connected to the ZONE2 (ZONE3) speaker terminals (
page 76).
• When a sold separately room-to-room remote control unit (DENON RC-616, 617 or 618) is wired and connected between the MAIN
ZONE and ZONE2 (ZONE3), the remote-controllable devices in the MAIN ZONE can be controlled from ZONE2 (ZONE3) using the
remote control unit.
To control playback devices other than the ones above, either use that device’s remote control unit or preset a separately sold
programmable remote control unit.
Multi zone music entertainment system
• For instructions on installation and operation of separately sold devices, refer to the devices’ operating instructions.
Multi-zone playback using the ZONE2 and ZONE3 PREOUT terminals
2
When using the power amplifier as the MAIN ZONE output
• The AVR-4306 is equipped with pre-out terminals for which the volume is adjustable and video output terminals (composite and S-
Video) as the ZONE2 output terminals, and variable output level as the ZONE3 output terminals.
[System configuration and connections example]
Using external amplifier.
AVR-4306
DVD player
Input
RC-616
Monitor
MAIN ZONE 7.1-channel system
ZONE2 AUDIO OUT
(VARIABLE OUT)
SYSTEM REMOTE
CONTROL UNIT RC-1024
ZONE3 AUDIO OUT (VARIABLE OUT)
PROGRAMMABLE
REMOTE CONTROL UNIT
RC-617
RC-617
PROGRAMMABLE
REMOTE
CONTROL UNIT
ZONE2
VIDEO OUT
C
FL
FR
SL
SW
SR
SB
R
SB
L
Power
Amplifer
Power
Amplifer
ZONE 2
ZONE 3
Monitor
:
MULTI SOURCE AUDIO signal cable
:
MULTI SOURCE VIDEO signal cable
: ROOM-TO-ROOM REMOTE CONTROL SYSTEM
(separately sold) control line
Refer to “Connections” (
page 22).