Admin Status: Down
![]() |
View all Lantronix S3220 Series manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 437 highlights
Transition Networks ION x222x / x32xx User Guide Invalid input found! This message indicates that you entered a parameter outside the valid range (e.g., VLAN ID = 0). 1. Verify the parameter value to be entered; check the online Help for valid input information. 2. Retry the operation. 3. If the problem persists, contact Technical Support. See Contact Us below. Invalid password! This message indicates that the password entered during sign on is not valid. 1. Sign in using the correct password. The default password is private. Note: the password is case sensitive. 2. If the problem persists, contact Technical Support. See Contact Us below. Failed to retrieve DMI info on current port. You clicked the Device port's DMI tab, but the device does not support DMI. Not all NID models support DMI. The NIDs and SFPs that support DMI have a "D" at the end of the model number. 1. Verify that the NID and SFP support DMI. 2. See "DMI (Diagnostic Maintenance Interface) Parameters" on page 248 for more information. 3. Retry the operation. 4. If the problem persists, contact Technical Support. See Contact Us below. Admin Status: Down (or Testing) In the device's port, at the MAIN tab in the Port Configuration section, the Admin Status field displays "Down". Typically, if 'Admin Status' is Down, then 'Link Status' is also Down. The status here is the desired state of the interface. The "Testing" status indicates that no operational packets can be passed. When a managed system initializes, all interfaces start with 'Admin Status' in the Down state. As a result of either explicit management action or per configuration information retained by the managed system, 'Admin Status' is then changed to either the Up or Testing states, or remains in the Down state. 1. Verify the initialization process; see "Section 2: Installation and System Setup" on page 40. 2. Verify the attempted operation procedure in the related section of this manual. 3. Retry the operation. Wait several minutes for initialization and discovery to take place. 4. If the problem persists, contact Technical Support. See Contact Us below. Link Status: Down (or Testing or Dormant, or NotPresent) This is the current operational state of the interface. The 'Link Status' Testing state indicates that no operational packets can be passed. If 'Admin Status' is Down then 'Link Status' likely will be Down. 33472 Rev. J https://www.transition.com Page 437 of 700
![](/manual_guide/products/lantronix-s3220-series-user-guide-rev-j-pdf-3475-mb-2c29388/437.png)