There is no problem with Printhead Nozzles: The Nozzle Health Test shows OK in every zone. The Printhead
View all HP Jet Fusion 300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 85 highlights
● RA or Out = "Underperforming" 1. There is no problem with Printhead Nozzles: The Nozzle Health Test shows OK in every zone. The Printhead Health Gauge will show "Printhead is performing as expected:" 2. Printhead has relatively few clogged nozzles: The Nozzle Health Test shows MON in any zone. The Printhead Health Gauge will show "Printhead has clogged nozzles:" 3. Printhead has several clogged nozzles, which may produce defects in the printed parts: The Nozzle Health Test shows with RA or Out in any zone. The Printhead Health Gauge will show "Printhead is underperforming:" How to update the Printhead Health Gauge status 79
●
RA or Out = “Underperforming”
1.
There is no problem with Printhead Nozzles: The Nozzle Health Test shows OK in every zone. The Printhead
Health Gauge will show “Printhead is performing as expected:”
2.
Printhead has relatively few clogged nozzles: The Nozzle Health Test shows MON in any zone. The Printhead
Health Gauge will show “Printhead has clogged nozzles:”
3.
Printhead has several clogged nozzles, which may produce defects in the printed parts: The Nozzle
Health Test shows with RA or Out in any zone. The Printhead Health Gauge will show “Printhead is
underperforming:”
How to update the Printhead Health Gauge status