Lantronix EDS2100 EDS1100 / EDS2100 - User Guide - Page 59
Tunnel - Connect Mode, Settings continued, Description
View all Lantronix EDS2100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 59 highlights
8: Line and Tunnel Settings Tunnel - Connect Mode Description Settings (continued) Reconnect Timer Enter the reconnect time in milliseconds. The device attempts to reconnect after this amount of time after failing a connection or exiting an existing connection. This behavior depends upon the Disconnect Mode. Note: When you configure Tunnel - Connect Mode, you can specify a number of milliseconds to attempt to reconnect after a dropped connection has occurred. The default is 1500 milliseconds. The Reconnect Timer only applies if a Disconnect Mode is configured. With a Disconnect Mode set, the device server maintains a connection until the disconnect mode condition is met (at which time the device server closes the connection). If the tunnel is dropped due to conditions beyond the device server, the device server attempts to re-establish a failed connection when the specified reconnect interval reaches its limit. Any network-side disconnect is considered an error and a reconnect is attempted without regard to the Connect Mode settings. Simultaneous Connect Mode connections require some Disconnect Mode configurations or the connections will never terminate. See Tunnel - Disconnect Mode on page 61 for more information about the parameters. If Disconnect Mode is disabled and the network connection is dropped, then the re-establishment of a tunnel connection is governed by the configured Connect Mode settings. Flush Serial Data Select whether to flush the serial line when a connection is made. Choices are: Enabled = flush the serial line when a connection is made. Disabled = do not flush the serial line. (default) Block Serial Select Enabled to block (not tunnel) serial data transmitted to the device. This is a debugging tool that causes serial data sent to the device to be ignored. Block Network Select Enabled to block (not tunnel) network data transmitted to the device. This is a debugging tool that causes network data sent to the device to be ignored. Email on Connect Select whether the device sends an email when a connection is made. Select None if you do not want to send an email. Otherwise, select the Email profile to use. Email on Disconnect Select whether the device sends an email when a connection is closed. Select None if you do not want to send an email. Otherwise, select the Email profile to use. 3. Click Submit. The host is configured. A second host appears underneath the newly configured host. 4. Repeat these steps to configure additional hosts as necessary. EDS1100/2100 supports configuration of up to sixteen hosts. EDS1100/2100 User Guide 59