Lantronix EDS2100 EDS1100 / EDS2100 - User Guide - Page 55

Flush Serial Data, Block Serial Data, Block Network, Password, Email on Connect, Email on Disconnect

Page 55 highlights

8: Line and Tunnel Settings Tunnel - Accept Mode Settings (continued) Flush Serial Data Block Serial Data Block Network Password Email on Connect Email on Disconnect Description Select Enabled to flush the serial data buffer on a new connection. Select On to block, or not tunnel, serial data transmitted to the device. Select On to block, or not tunnel, network data transmitted to the device. Enter a password that clients must send to the device within 30 seconds from opening a network connection to enable data transmission. The password can have up to 31 characters and must contain only alphanumeric characters and punctuation. When set, the password sent to the device must be terminated with one of the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR LF), or (d) 0x0D 0x00. Select whether the device sends an email when a connection is made. Select None if you do not want to send an email. Otherwise, select the Email profile to use for sending. Select whether the device sends an email when a connection is closed. Select None if you do not want to send an email. Otherwise, select the Email profile to use for sending. 3. Click Submit. 4. Repeat these steps to configure additional tunnels as applicable. EDS1100/2100 User Guide 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

8: Line and Tunnel Settings
EDS1100/2100 User Guide
55
3.
Click
Submit.
4.
Repeat these steps to configure additional tunnels as applicable.
Flush Serial Data
Select Enabled to flush the serial data buffer on a new connection.
Block Serial Data
Select On to block, or not tunnel, serial data transmitted to the
device.
Block Network
Select On to block, or not tunnel, network data transmitted to the
device.
Password
Enter a password that clients must send to the device within 30 seconds from
opening a network connection to enable data transmission.
The password can have up to 31 characters and must contain only alphanumeric
characters and punctuation. When set, the password sent to the device must be
terminated with one of the following: (a) 0x0A (LF), (b) 0x00, (c) 0x0D 0x0A (CR
LF), or (d) 0x0D 0x00.
Email on Connect
Select whether the device sends an email when a connection is made. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use for sending.
Email on Disconnect
Select whether the device sends an email when a connection is closed. Select
None if you do not want to send an email. Otherwise, select the Email profile to
use for sending.
Tunnel -
Accept Mode
Settings (continued)
Description