Lantronix EDS2100 EDS1100 / EDS2100 - User Guide - Page 44

Line and Tunnel Settings, EDS1100/2100 User Guide, Parity, Data Bits, Stop Bits, Flow Control

Page 44 highlights

8: Line and Tunnel Settings Line - Configuration Description Settings (continued) Parity Select the parity from the drop-down menu. The default is None. Data Bits Select the number of data bits from the drop-down menu. The default is 8. Stop Bits Select the number of stop bits from the drop-down menu. The default is 1. Flow Control Select the flow control from the drop-down menu. The default is None. Xon Char Specify the character to use to start the flow of data when Flow Control is set to Software. Prefix a decimal character with \ or a hexadecimal character with 0x, or provide a single printable character. The default Xon char is 0x11. Xoff Char Specify the character to use to stop the flow of data when Flow Control is set to Software. Prefix a decimal character with \ or a hexadecimal character with 0x, or provide a single printable character. The default Xoff char is 0x13. Gap Timer The driver forwards received serial bytes after the Gap Timer delay from the last character received. By default, the delay is four character periods at the current baud rate (minimum 1 ms). Threshold The driver will also forward received characters after Threshold bytes have been received. 3. Click Submit. 4. Repeat above steps as desired, according to additional line(s) available for your product. EDS1100/2100 User Guide 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152

8: Line and Tunnel Settings
EDS1100/2100 User Guide
44
3.
Click
Submit.
4.
Repeat above steps as desired, according to additional line(s) available for your product.
Parity
Select the parity from the drop-down menu. The default is None.
Data Bits
Select the number of data bits from the drop-down menu. The default is 8.
Stop Bits
Select the number of stop bits from the drop-down menu. The default is 1.
Flow Control
Select the flow control from the drop-down menu. The default is None.
Xon Char
Specify the character to use to start the flow of data when Flow Control is
set to Software. Prefix a decimal character with \ or a hexadecimal
character with 0x, or provide a single printable character. The default Xon
char is 0x11.
Xoff Char
Specify the character to use to stop the flow of data when Flow Control is
set to Software. Prefix a decimal character with \ or a hexadecimal
character with 0x, or provide a single printable character. The default Xoff
char is 0x13.
Gap Timer
The driver forwards received serial bytes after the
Gap Timer
delay from
the last character received. By default, the delay is four character periods at
the current baud rate (minimum 1 ms).
Threshold
The driver will also forward received characters after
Threshold
bytes have