Epson SureLab D3000 Administrator Guide - Page 58

Manual Adjustment, Clear, Click, from Print Check Pattern., Prints the check pattern.

Page 58 highlights

Settings/Maintenance Note: O The tone curve shows the output strength for each input color (R: Red, G: Green, B: Blue). When in an uncorrected state (a straight line from top right to bottom left), the image darkens (colors become deeper) when moved down, and the image lightens (the colors become paler) when moved up. O You can manually adjust the density by using Manual Adjustment on the right of the screen. If you make manual adjustments, the Pattern Adjustment value becomes unavailable. O When you click Clear, the Density adjustment values are returned to their default values. The Color Balance and Gradation values are retained. G Click Print from Print Check Pattern. Prints the check pattern. Check that the color balance is as intended. H Click Apply. The settings are applied and the screen is closed. 58

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Settings/Maintenance
58
G
Click
Print
from Print Check Pattern.
Prints the check pattern.
Check that the color balance is as intended.
H
Click
Apply
.
The settings are applied and the screen is closed.
Note:
O
The tone curve shows the output strength for each input color (R: Red, G: Green, B: Blue). When in an
uncorrected state (a straight line from top right to bottom left), the image darkens (colors become deeper)
when moved down, and the image lightens (the colors become paler) when moved up.
O
You can manually adjust the density by using
Manual Adjustment
on the right of the screen. If you make
manual adjustments, the Pattern Adjustment value becomes unavailable.
O
When you click
Clear
, the Density adjustment values are returned to their default values. The Color Balance
and Gradation values are retained.