Epson SureLab D3000 Administrator Guide - Page 37

Calibration

Page 37 highlights

Settings/Maintenance Calibration Click Calibration (0341) from Color Calibration (034) to display the screen. You can perform calibration by using the following work flow. Create Correction Value Print Measure Color Create Correction Value Print a correction chart: Prints a chart for adjustment. Measure color for the correction chart: Perform color measurement for the printed chart on the Client PC with a connected color measurement device. Creating a correction value: Create a correction value file. Correction Value Verification Print Measure Color Write Print a verification chart: Prints a verification chart. Measure color for the verification chart: Perform color measurement for the printed chart on the Client PC with a connected color measurement device. Verify correction accuracy: Verify the accuracy of the created correction value to complete the correction value file creation process. Tip: O After adjusting values for Gray Adjustment, perform Color Calibration, and then make the settings again. U "Gray Adjustment" on page 50 O Click Date of Adjustment to display the time when it was last adjusted. You can check the changed date settings for each Paper Surface Type. 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Settings/Maintenance
37
Calibration
Click
Calibration
(0341) from Color Calibration (034) to display the screen.
You can perform calibration by using the following work flow.
Create Correction
Value
Print
Print a correction chart: Prints a chart for adjustment.
Measure Color
Measure color for the correction chart:
Perform color measurement for the printed chart on the Client PC with a
connected color measurement device.
Create Correction Value
Creating a correction value: Create a correction value file.
Correction Value
Verification
Print
Print a verification chart: Prints a verification chart.
Measure Color
Measure color for the verification chart:
Perform color measurement for the printed chart on the Client PC with a
connected color measurement device.
Write
Verify correction accuracy:
Verify the accuracy of the created correction value to complete the
correction value file creation process.
Tip:
O
After adjusting values for Gray Adjustment, perform
Color Calibration
, and then make the settings again.
U
“Gray Adjustment” on page 50
O
Click
Date of Adjustment
to display the time when it was last adjusted. You can check the changed date settings for
each Paper Surface Type.