Epson SureLab D3000 Administrator Guide - Page 34

Periodic Nozzle Check Settings, Apply

Page 34 highlights

Settings/Maintenance Periodic Nozzle Check Settings From the CR Unit Adjustment/Maintenance (03) menu, click Periodic Nozzle Check Settings (0313) from Head Cleaning (031) to display the screen. Set whether or not to perform auto nozzle check. We recommend that this is set to ON, because if it is set to OFF the user needs to manually check for clogging. After changing settings, click Apply to apply the changes. Item ON Perform [Auto Cleaning] during Pre-operation Check. OFF Back Help Apply Explanation Nozzle Check is performed automatically during Pre-operation Check, when a print order starts and when a print order finishes. Select whether or not to perform cleaning automatically if the nozzle check detects a clog in the print head during the Pre-operation Check. When selected, cleaning is performed automatically and a clogging detected message (1501) is only displayed if the clog is not cleared. When performing cleaning, the time needed for the Pre-operation Check is increased by a few minutes. When not selected, a message is displayed without performing cleaning if the nozzle check detects a clog in the print head during the Pre-operation Check. Auto nozzle check is not performed. Click to close the Settings/Maintenance screen. Click to display the Help. Click to apply any changed settings. 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Settings/Maintenance
34
Periodic Nozzle Check Settings
From the CR Unit Adjustment/Maintenance (03) menu, click
Periodic Nozzle Check Settings
(0313) from Head
Cleaning (031) to display the screen.
Set whether or not to perform auto nozzle check.
We recommend that this is set to ON, because if it is set to OFF the user needs to manually check for clogging.
After changing settings, click
Apply
to apply the changes.
Item
Explanation
ON
Nozzle Check is performed automatically during Pre-operation Check, when a print order starts
and when a print order finishes.
Perform [Auto Cleaning]
during Pre-operation
Check.
Select whether or not to perform cleaning automatically if the nozzle check detects a clog in the
print head during the Pre-operation Check. When selected, cleaning is performed automatically
and a clogging detected message (1501) is only displayed if the clog is not cleared. When
performing cleaning, the time needed for the Pre-operation Check is increased by a few
minutes.
When not selected, a message is displayed without performing cleaning if the nozzle check
detects a clog in the print head during the Pre-operation Check.
OFF
Auto nozzle check is not performed.
Back
Click to close the Settings/Maintenance screen.
Help
Click to display the Help.
Apply
Click to apply any changed settings.