Epson SureLab D3000 Administrator Guide - Page 55
Print, Apply, Manual Adjustment, Clear
View all Epson SureLab D3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Settings/Maintenance Note: O The tone curve shows the output strength for each input color (R: Red, G: Green, B: Blue). When in an uncorrected state (a straight line from top right to bottom left), the image darkens (colors become deeper) when moved down, and the image lightens (the colors become paler) when moved up. O You can manually adjust the color by using Manual Adjustment on the right of the screen. If you make manual adjustments, the Pattern Adjustment value becomes unavailable. O When you click Clear, the Color Balance adjustment values are returned to their default values. The Density and Gradation values are retained. H Click Print from Print Check Pattern. Prints the check pattern. Check that the color balance is as intended. I Click Apply. The settings are applied and the screen is closed. 55