Epson SureLab D3000 Administrator Guide - Page 40

Correction chart color measurement (for the \, Measure Color, Color Measurement Method, Line Scan

Page 40 highlights

Settings/Maintenance Correction chart color measurement (for the "i1Pro") A Check that the color measurement device you want to use is connected. Tip: For more information on color measurement device, see the document supplied with the device. B Click Measure Color from Correction Value Creation Phase. D Place the correction chart that matches the color chart ID and preset ID displayed on the screen on the measurement backup board supplied with the color measurement device. Place the chart on white paper if there is no backup board available for measurement. C Place the color measurement device on the calibration base plate, and then click OK. Performs color measurement for the white calibration tile. Tip: O The color chart ID and preset ID are printed at the bottom of the correction chart. O If a correction chart sticks out beyond the edge of the measurement backup board, cut off the margin along the cutoff line on the chart. E Click OK. Color measurement starts. F Select Color Measurement Method. Select a Line Scan to perform color measurement for each line, or select Spot Scan to perform color measurement for each patch. 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

Settings/Maintenance
40
Correction chart color measurement (for the
"i1Pro")
A
Check that the color measurement device you
want to use is connected.
B
Click
Measure Color
from Correction Value
Creation Phase.
C
Place the color measurement device on the
calibration base plate, and then click
OK
.
Performs color measurement for the white
calibration tile.
D
Place the correction chart that matches the color
chart ID and preset ID displayed on the screen
on the measurement backup board supplied
with the color measurement device.
Place the chart on white paper if there is no
backup board available for measurement.
E
Click
OK
.
Color measurement starts.
F
Select
Color Measurement Method
.
Select a
Line Scan
to perform color
measurement for each line, or select
Spot Scan
to perform color measurement for each patch.
Tip:
For more information on color measurement
device, see the document supplied with the
device.
Tip:
O
The color chart ID and preset ID are printed
at the bottom of the correction chart.
O
If a correction chart sticks out beyond the
edge of the measurement backup board, cut
off the margin along the cutoff line on the
chart.