Dell DSS 2500 Owners Manual - Page 97

Removing an expansion card on the internal PERC riser

Page 97 highlights

Figure 43. Removing an expansion card on the internal PERC riser 1. expansion card guide slot on internal PERC riser 3. internal PERC riser 5. release tab 2. expansion card 4. PCIe connector on internal PERC riser card 6. locking notch on the expansion card Next steps 1. Follow the procedure listed in the After working inside your system section. 2. Install the internal PERC riser on the system board. 3. Install the cooling shroud. 4. If removed, reinstall the dual riser module. NOTE: If required, open the expansion card latch on the cooling shroud to support the full length card. 5. Reconnect the disconnected cables to the expansion card(s). Related references Safety instructions on page 53 Related tasks Before working inside your system on page 53 Removing the dual riser module (optional) on page 92 Removing the cooling shroud on page 59 Removing the internal PERC riser on page 94 Installing an expansion card into the internal PERC riser on page 98 Installing the internal PERC riser on page 95 Installing the cooling shroud on page 60 Installing the dual riser module (optional) on page 93 After working inside your system on page 54 Installing and removing system components 97

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157

Figure 43. Removing an expansion card on the internal PERC riser
1.
expansion card guide slot on internal PERC riser
2.
expansion card
3.
internal PERC riser
4.
PCIe connector on internal PERC riser card
5.
release tab
6.
locking notch on the expansion card
Next steps
1.
Follow the procedure listed in the After working inside your system section.
2.
Install the internal PERC riser on the system board.
3.
Install the cooling shroud.
4.
If removed, reinstall the dual riser module.
NOTE:
If required, open the expansion card latch on the cooling shroud to support the full length card.
5.
Reconnect the disconnected cables to the expansion card(s).
Related references
Safety instructions
on page 53
Related tasks
Before working inside your system
on page 53
Removing the dual riser module (optional)
on page 92
Removing the cooling shroud
on page 59
Removing the internal PERC riser
on page 94
Installing an expansion card into the internal PERC riser
on page 98
Installing the internal PERC riser
on page 95
Installing the cooling shroud
on page 60
Installing the dual riser module (optional)
on page 93
After working inside your system
on page 54
Installing and removing system components
97