Adaptec 2930U User Guide - Page 67

Parameters, Add Key, Device, Add Value, Enter

Page 67 highlights

Using Advanced Configurable Parameters in Windows NT 4.0 6 In the Key Name edit box, type Parameters. Leave the Class edit box blank. 7 Click Parameters. 8 From the Edit menu, select Add Key. 9 In the Key Name edit box, type Device.To specify a SCSI card, type the number of the SCSI card after Device. For example, type Device0 for the first SCSI card, type Device1 for the second, and so on. If you omit the SCSI card number, the configuration information may be applied to other SCSI cards installed in your computer. Leave the Class edit box blank. 10 Click Device. 11 From the Edit menu, select Add Value. 12 In the Key Name edit box, type DriverParameters, then type REG_SZ as the data type and press Enter. 13 A String Editor text box appears. Enter valid parameters in the text box. When entering multiple parameters, each parameter must be separated by a space. Note: Changes made with the Registry Editor do not take effect until you shut down and then restart your system. C-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

C-5
Using Advanced Configurable Parameters in Windows NT 4.0
6
In the Key Name edit box, type
Parameters
. Leave the Class
edit box blank.
7
Click
Parameters
.
8
From the Edit menu, select
Add Key
.
9
In the Key Name edit box, type
Device.
To specify a SCSI card,
type the number of the SCSI card after
Device
.
For example, type
Device0
for the first SCSI card, type
Device1
for the second, and so on. If you omit the SCSI card
number, the configuration information may be applied to other
SCSI cards installed in your computer.
Leave the Class edit box blank.
10
Click
Device
.
11
From the Edit menu, select
Add Value
.
12
In the Key Name edit box, type
DriverParameters
, then type
REG_SZ
as the data type and press
Enter
.
13
A String Editor text box appears. Enter valid parameters in the
text box. When entering multiple parameters, each parameter
must be separated by a space.
Note:
Changes made with the Registry Editor do not take
effect until you shut down and then restart your system.