Adaptec 2930U User Guide - Page 64

Value Keys for SCSI Parameters

Page 64 highlights

Using Advanced Configurable Parameters in Windows NT 4.0 Note: The following value keys are case-sensitive and must be entered exactly as shown. Value Keys for SCSI Parameters I DisableTaggedQueuing-A nonzero value indicates that the SCSI card disables tagged queueing for SCSI devices. The data type for this value is REG_SZ. I DisableSynchronousTransfers-A nonzero value indicates that the SCSI card is not to initiate synchronous negotiations (but it may still accept negotiations initiated by a SCSI target). The data type for this value is REG_SZ. I DisableDisconnects-A nonzero value indicates that targets are not permitted to disconnect during the execution of a SCSI command. The data type for this value is REG_DWORD. I MaximumLogicalUnit-This can limit the scan for connected devices on the SCSI bus. Valid values are 1 to 8. If 1 is specified, the Windows NT SCSI Manager assumes that no SCSI targets support LUNs other than 0. Otherwise, LUNs from 0 to 8 are scanned during system initialization. The data type for this value is REG_DWORD. I Maximum SGList- Specifies the maximum number of Scatter/Gather elements. Valid values are 17 to 255. The data type for this value is REG_DWORD. To enter Windows NT parameters 1 Click Start, then click Run. 2 Type regedt32, then press Enter. 3 Open the registry list to \HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\ aic78xx\Parameters\Device. If the \Parameters\Device keys already exist, skip to Step 9 to begin entering values. If the keys do not exist, create them by continuing with Step 4. 4 Click aic78xx. C-2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

C-2
Using Advanced Configurable Parameters in Windows NT 4.0
Note:
The following value keys are case-sensitive and must be
entered exactly as shown.
Value Keys for SCSI Parameters
DisableTaggedQueuing
—A nonzero value indicates that the
SCSI card disables tagged queueing for SCSI devices. The data
type for this value is
REG_SZ
.
DisableSynchronousTransfers
—A nonzero value indicates
that the SCSI card is not to initiate synchronous negotiations
(but it may still accept negotiations initiated by a SCSI target).
The data type for this value is
REG_SZ
.
DisableDisconnects
—A nonzero value indicates that targets
are not permitted to disconnect during the execution of a SCSI
command. The data type for this value is
REG_DWORD.
MaximumLogicalUnit
—This can limit the scan for connected
devices on the SCSI bus. Valid values are 1 to 8. If 1 is specified,
the Windows NT SCSI Manager assumes that no SCSI targets
support LUNs other than 0. Otherwise, LUNs from 0 to 8 are
scanned during system initialization. The data type for this
value is
REG_DWORD
.
Maximum SGList
— Specifies the maximum number of
Scatter/Gather elements. Valid values are 17 to 255. The data
type for this value is
REG_DWORD
.
To enter Windows NT parameters
1
Click
Start
, then click
Run
.
2
Type
regedt32
, then press
Enter
.
3
Open the registry list to
\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\
aic78xx\Parameters\Device.
If the
\
Parameters\Device
keys already exist, skip to
Step 9
to
begin entering values. If the keys do not exist, create them by
continuing with Step 4.
4
Click
aic78xx
.