Continued on next Put a check mark in the Select column., Touch [Setng]., Change the settings.
![]() |
View all Panasonic WU-192ME2U9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 314 highlights
1 2 3 4 5 6 7 8 8 9 8. Intelligent Controller (CZ-256ESMC2U) Editing settings 1 Put a check mark in the "Select" column. z You can select more than one. 1 2 Touch [Setng]. z The "Edit unit settings" dialogue is displayed. 2 3 Change the settings. Basic settings on the indoor unit Item O/D unit address I/D unit address Display CNTR addr. Fix cap ElecHeatrCap Group registration y Control Gr. y SchedleGroup y Area y Distrib. Grp. Not batch Not managed Explanation Use to set the addresses of the outdoor units (1 to 31). ("31" is set for interface adaptors) Use to set the addresses of the indoor units (1 to 64). Use to set the order when displayed in a list (0 to 256). Set the central addresses (1 to 64). Touch the text box and enter with the touchscreen numeric keypad. Note y The central address is shared with other centralised controllers (system controllers, etc.). Do not change unless necessary. y An error message is displayed if you set an address that is already in use. y This cannot be set if multiple indoor units are selected. Set the fixed capacity values of the indoor unit. (When interface adaptors are installed) Touch the text box and enter with the touchscreen numeric keypad. Set the capacity of the electric heater if the model has an electric heater. (when calculating load distribution) Touch the text box and enter with the touchscreen numeric keypad. Register the group the unit belongs to. The group names are displayed when you touch the text boxes. Note y By putting a check mark in the "Select" column of the indoor units belonging to the same group, you can edit the settings at the same time and register them all together. Select "" if the device is not to be subject to operations and select "" if it is to be subject to operations. Select "" if the device is to be remove as a subject of management by this unit, and select "" if it is to be subject of management by this unit. Continued on next page Configuring the system 4 Touch [Register]. z To cancel the settings, touch [Cancel]. 4 5 Touch [Register]. z To cancel the settings, touch [Cancel]. 5 Basic settings on the indoor unit Automatically setting central addresses 1 Put a check mark in the "Register" column. z Select the indoor units you want to manage. 1 2 Touch [CNTR adr AutSet]. 2 Note y The central address is shared with other centralised controllers (system controllers, etc.). Do not change unless necessary. y After setting the central address in the "Edit unit settings" dialogue, and then enable [CNTR adr AutSet], the central addresses will be overwritten. Configuring the system 3 - 242 Setting Setting Control of 2WAY VRF SYSTEM Item Name Explanation Change the name of the indoor unit. Touch the text box and enter with the touchscreen keyboard. You can enter up to 16 letters or numbers. $;&4.$6@0*QEG 143 $;&4.$6@0*QEG 144
![](/manual_guide/products/panasonic-u72me2u9-technical-data-manual-ec761eb/314.png)