Panasonic WU-192ME2U9 Technical Data Manual - Page 139
RC. setting mode, Detailed settings, Auto address, Set elec. consumption, Attention
View all Panasonic WU-192ME2U9 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 139 highlights
3. High-spec Wired Remote Controller (CZ-RTC5A) 3 - 67 Setting RC. setting mode (Main/sub, Clock type, Password change) Detailed settings (Vent output setting, Temp sensor setting, Temp display setting) 1 Press and hold the 3 buttons for 4 seconds or more simultaneously. , ,► 2 Select the item to set RC. setting mode 3 Set. (Select the Code no. and Set data.) Repeat) Code no. Set data Code no. 01 Main/sub Set this when using 2 remote controllers. 02 Clock type Set the type of clock display. Display of Set whether to display the operation lock cancelling method on the 36 operation lock lock screen while operation is locked. (For the lock screen, see the cancelling method "Part Names" section in the Quick Reference.) 2F Password change Set the administrator password. Set data • 0000: Sub • 0001: Main (factory setting) • 0000: 24 hours • 0001: 12 hours (AM/PM) • 0000: Displayed (factory setting) • 0001: Not displayed • 0000 to 9999 • 0000 (factory setting) Detailed settings 3 Set. (Select the indoor unit number, Code no. and Set data.) Repeat) Code no. 31 Vent output setting 32 Temp sensor setting 33 Temp display setting Indoor unit Set data number Code no. Set data Set this when connecting a commercially sold fan, etc. to the ventilation fan output "FAN DRIVE:2P (White)" on the indoor control board. *Dedicated cables (optional) are required. • • 0000: Not connected 0001: Connected Set this when measuring the room temperature with the room temperature sensor of the remote controller. • • When using the main and sub controllers, the main one is enabled. When controlling in group, set this for the main indoor unit number. (No setting is required for sub indoor units.) • • 0000: Indoor unit 0001: RC • When using with the remote sensor in combination, set the indoor unit setting data. Set the type of temperature display. • 0000: °C • 0001: °F 11 Setting Auto address Set elec. consumption Auto address 3 Set. (Select the Code no. [A1] and O/D unit no.) Repeat) Code no. A1 Set the Auto address for each O/D unit no. Select the O/D unit no. (outdoor unit) for Auto address. Code no. O/D unit no. • Outdoor unit number O/D unit no. Note After RC. setting mode, Detailed settings or Auto address is complete, the unit restarts. Attention Set Auto address after all units are turned on and 1 minute and 30 seconds or more have passed. Operate the units after Auto address is set and 1 minute and 30 seconds or more have passed. Set elec. consumption 3 Set. (Select the power supply voltage of outdoor units Note Set the power supply voltage of outdoor units to calculate electric consumption of the Power consumption monitor. If the setting differs from the power supply voltage of outdoor units, the electricity display error may occur. Depending on the outdoor unit model, this cannot be set. When 3-phase model connections are used for outdoor units Power supply voltage 380 V 400 V 415 V Setting value 220 V 230 V 240 V 12 Control of 2WAY VRF SYSTEM 35 JOEE 35 JOEE 1 2 3 4 5 6 7 8 9