LiftMaster JHDC Installation Manual - English French Spanish - Page 36

DEVICE, Door at Open Mid-Stop

Page 36 highlights

Programming (continued) WIRING TYPE DEVICE ACTION STATE Operator at OPEN limit Operator at CLOSE limit OPEN button is pressed momentarily Door opening Door closing Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit 3-Button Remote Control CLOSE button Programmed as is pressed OPEN/CLOSE/ momentarily STOP Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop Door stopped during open or close cycle Operator at OPEN limit Single Button Remote Control Button is Programmed pressed C2 (continued) as SBC Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during open cycle Door stopped during close cycle Operator at OPEN limit Operator at CLOSE limit Single Button Wall Controller (Wired) Button is pressed Door opening Door closing Door at Open Mid-Stop Door stopped during open cycle Door stopped during close cycle Button is held (constant pressure) Door Opening Operator at OPEN limit Operator at CLOSE limit Door opening Open is pressed Door closing Door at Open Mid-Stop myQ® Smart Facility Access Door stopped during open or close cycle Operator at OPEN limit Operator at CLOSE limit Door opening Close is pressed Door closing Door at Open Mid-Stop Door stopped during open or close cycle RESPONSE No change in state Door opens to the OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door opens to the OPEN limit or Mid-Stop No change in state No change in state No change in state No change in state No change in state No change in state No change in state No change in state Door stops Door stops No change in state No change in state No change in state Door opens to the OPEN limit or Mid-Stop Door stops Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit No change in state Door opens to the OPEN limit or Mid-Stop Door closes and stops when button is released Door opens to the OPEN limit or Mid-Stop Door stops Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door closes and stops when button is released Door opens to the OPEN limit or Mid-Stop No change in state or Mid-Stop No change in state Door opens to the OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door opens to the OPEN limit or Mid-Stop No change in state No change in state No change in state No change in state No change in state No change in state 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216

36
Programming (continued)
WIRING
TYPE
DEVICE
ACTION
STATE
RESPONSE
C2
(continued)
3-Button
Remote Control
Programmed as
OPEN/CLOSE/
STOP
OPEN button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or
close cycle
Door opens to the OPEN limit or Mid-Stop
CLOSE button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
No change in state
Door stopped during open or
close cycle
No change in state
STOP button
is pressed
momentarily
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
Door stops
Door closing
Door stops
Door at Open Mid-Stop
No change in state
Door stopped during open or
close cycle
No change in state
Single Button
Remote Control
Programmed
as SBC
Button is
pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
Door stops
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open cycle
No change in state
Door stopped during close cycle
Door opens to the OPEN limit or Mid-Stop
Single Button
Wall Controller
(Wired)
Button is
pressed
Operator at OPEN limit
Door closes and stops when button is released
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
Door stops
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open cycle
Door closes and stops when button is released
Door stopped during close cycle
Door opens to the OPEN limit or Mid-Stop
Button is held
(constant
pressure)
Door Opening
No change in state or Mid-Stop
myQ
®
Smart
Facility Access
Open is pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
Door opens to the OPEN limit or Mid-Stop
Door opening
No change in state
Door closing
Door will auto reverse to OPEN limit or Mid-Stop
Door at Open Mid-Stop
Door opens to the OPEN limit
Door stopped during open or
close cycle
Door opens to the OPEN limit or Mid-Stop
Close is pressed
Operator at OPEN limit
No change in state
Operator at CLOSE limit
No change in state
Door opening
No change in state
Door closing
No change in state
Door at Open Mid-Stop
No change in state
Door stopped during open or
close cycle