LiftMaster JHDC Installation Manual - English French Spanish - Page 34
Set Operating Mode, WIRING, ACTION, STATE, RESPONSE
View all LiftMaster JHDC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Programming (continued) Determine and Set Operating Mode Select the operating mode for your application from the menu in the Wall Controller. WIRING TYPE DEVICE ACTION STATE RESPONSE Operator at OPEN limit No change in state Operator at CLOSE limit OPEN button is pressed momentarily Door opening Door closing Door at Open Mid-Stop Door opens to the OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door stopped during open or close cycle Door opens to the OPEN limit or Mid-Stop Operator at OPEN limit Door closes to the CLOSE limit CLOSE Operator at CLOSE limit button is Door opening pressed Door closing momentarily Door at Open Mid-Stop No change in state No change in state No change in state Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Operator at OPEN limit No change in state B2 Momentary contact to open,close Front panel buttons (membrane) and 3-Button Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door stops Door stops No change in state and stop, plus Wall Door stopped during open or close cycle No change in state wiring for Controller Operator at OPEN limit No change in state sensing device to reverse and auxiliary devices to open and close with open override. Programmable Mid-Stops available with this wiring type. Close Mid Stop available but not shown in table. Operator at CLOSE limit OPEN button is held Door opening (constant Door closing pressure) Door at Open Mid-Stop Door opens to the OPEN limit (bypasses MidStop) No change in state (bypasses Mid-Stop) Door will auto reverse to OPEN limit (bypasses Mid-Stop) Door opens to the OPEN limit Door stopped during open or close cycle Door opens to the OPEN limit (bypasses MidStop) CLOSE button is held (constant pressure) Operator at OPEN limit Door closes to the CLOSE limit Operator at CLOSE limit No change in state Door opening No change in state Door closing No change in state Door at Open Mid-Stop Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Compatible with 3-Button Station, 1-Button Station, 1 and 3-Button Operator at OPEN limit Operator at CLOSE limit OPEN button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door opens to closest OPEN limit or Mid-Stop No change in state Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Remote Door stopped during open or close cycle Door opens to the OPEN limit Control. Monitored Entrapment 3-Button Remote Control CLOSE button is Operator at OPEN limit Operator at CLOSE limit Door opening Door closes to the CLOSE limit No change in state No change in state Protection Programmed pressed Door closing No change in state (LMEP) Device required. as OPEN/ CLOSE/STOP momentarily Door at Open Mid-Stop Door closes to the CLOSE limit Door stopped during open or close cycle Door closes to the CLOSE limit Operator at OPEN limit No change in state Operator at CLOSE limit STOP button is pressed momentarily Door opening Door closing Door at Open Mid-Stop No change in state Door stops Door stops No change in state Door stopped during open or close cycle No change in state Operator at OPEN limit Door closes to the CLOSE limit Single Button Remote Control Programmed as SBC Button is pressed Operator at CLOSE limit Door opening Door closing Door at Open Mid-Stop Door stopped during the open cycle Door opens to the OPEN limit or Mid-Stop Door stops Door will auto reverse to OPEN limit or Mid-Stop Door opens to the OPEN limit Door closes to the CLOSE limit Door stopped during the close cycle Door opens to the OPEN limit or Mid-Stop 34