APPENDIX Code 67 68 69 70 71 72 73 74 75 80 81 82 83 84 91 93 95 96 99 Meaning Wireless edge triggered more than 3 minutes Wireless edge loss of monitoring Wireless edge triggered CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening Close input (EYE/EDGE) communication fault from other operator Open input (EYE/EDGE) communication fault from other operator Close input (EYE/EDGE) communication fault (expansion board) Open input (EYE/EDGE) communication fault (expansion board) Non-monitored device detected on the wireless safety system Force reversal RPM / STALL reversal Motor start failure Power board fault Normal operation Solution Check wired input for wiring issue or obstruction. Check wireless edge inputs. IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring. IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators. Check the connections between the main board and the expansion board. Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection. Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See Limit, Speed and Force Adjustment page 23. Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly. Operator attempted to run, no response from motor drive assembly. Check connector and harness. If connected properly and still not working, replace motor and/or motor drive. Check connections to power board. Power cycle and retry. Replace power board if issue persists. No action required Saved YES YES NO NO NO YES YES YES YES YES YES YES YES 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

57
Code
Meaning
Solution
Saved
67
Wireless edge triggered more than 3 minutes
Check wired input for wiring issue or obstruction.
YES
68
Wireless edge loss of monitoring
Check wireless edge inputs.
YES
69
Wireless edge triggered
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check inputs and wiring.
NO
70
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on main control board
NO
71
CLOSE EDGE triggered, causing reversal, NO
preventing close, or canceling TTC
72
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
73
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on expansion board.
NO
74
CLOSE EYE/EDGE triggered, causing reversal and
preventing close or canceling TTC
75
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
80
Close input (EYE/EDGE) communication fault from
other operator
Check inputs and communication method between operators, either wired
bus or radio. Ensure operator is powered. May have to erase the wireless
communication and reprogram the two operators.
YES
81
Open input (EYE/EDGE) communication fault from
other operator
82
Close input (EYE/EDGE) communication fault
(expansion board)
Check the connections between the main board and the expansion board.
YES
83
Open input (EYE/EDGE) communication fault
(expansion board)
84
Non-monitored device detected on the wireless
safety system
Non-monitored contact closure devices are not supported. Make sure
connected devices are monitored. Check edges for proper orientation and
resistive end cap connection.
YES
91
Force reversal
Check for obstruction. If no obstruction, check that the mechanical
assembly is engaged and free to move. See
Limit, Speed and Force
Adjustment
page 23
.
YES
93
RPM / STALL reversal
Check for obstruction. If no obstruction, check the operator wiring and
that the mechanical assembly is engaged and free to move. Replace APE
assembly.
YES
95
Motor start failure
Operator attempted to run, no response from motor drive assembly. Check
connector and harness. If connected properly and still not working,
replace motor and/or motor drive.
YES
96
Power board fault
Check connections to power board. Power cycle and retry. Replace power
board if issue persists.
YES
99
Normal operation
No action required
YES