LiftMaster HDSL24UL Installation Manual - English - Page 33
ACCESSORY WIRING, External Control Devices, EXIT (2 Terminals), INTERRUPT (2 Terminals)
View all LiftMaster HDSL24UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
ACCESSORY WIRING All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. External Control Devices Access control device wiring NOT TO BE USED AS ENTRAPMENT PROTECTION EXIT (2 Terminals) This input is a soft open command (maintained switch does not override external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open. • Opens a closed or closing gate and holds open an open gate, if maintained, pauses Timer-to-Close at OPEN limit. Exit Com Control board SHADOW (2 Terminals) This input is used for external shadow loop detector when loop is positioned under the swing of the gate. • Holds open gate at open limit • Only active when the gate is at the OPEN limit, disregarded at all other times • Pauses Timer-to-Close at OPEN limit INTERRUPT (2 Terminals) This input is used for an external interrupt loop detector when loop is on the outside of the gate. • Holds open gate at open limit • Stops and reverses a closing gate to open limit • Pauses Timer-to-Close at OPEN limit, activates quick close and anti- tailgate features when enabled on the expansion board Loop wiring Control board Exit Com Shadow Com Interrupt Com Access Control Device Interrupt Loop Exit Loop 33