LiftMaster HDSL24UL Installation Manual - English - Page 36
Auxiliary Relays, Cycle count
View all LiftMaster HDSL24UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
EXPANSION AND RELAY ADAPTER BOARDS Auxiliary Relays The expansion board and relay adapter board provide Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. Function of relay contact activation determined by switch settings. AUX RELAY SETTING Off (no feature selected) Open Limit Switch Close Limit Switch Gate Motion Pre-Motion Delay Expansion Board Only Power Tamper Cycle Count - Expansion Board Only SWITCH SETTINGS 123 AUX RELAY 1 AUX RELAY 2 OFF OFF OFF Relay always off. Use this Aux Relay setting to conserve battery power. OFF OFF ON Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate). OFF ON OFF Energizes when not at close limit. For an additional audible or visual display, connect an external light (low voltage). Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an external buzzer or light (low OFF ON ON voltage). Energizes 3 seconds before gate motion and remains energized Energizes 3 seconds before gate motion and remains energized during gate motion. The onboard alarm will sound. For an during gate motion. For an additional audible or visual display, ON OFF OFF additional audible or visual display, connect an external buzzer or connect an external buzzer or light (low voltage). light (low voltage). Energizes when AC power or solar power is present. There is Energizes when on battery power. There is approximately a 10-12 ON ON OFF approximately a 10-12 second delay before relay cutoff, after AC second delay before relay cutoff, after AC shutdown. shutdown. ON OFF ON Energizes if gate is manually tampered with by being pushed off of close limit. For an additional audible or visual display, connect an external buzzer or light (low voltage). The 1, 2, and 3 LEDs will blink out the cycle count (cycle count is Red/green light functionality, see below. ON ON ON stored on the control board). See below. * Cycle count First, note the current Aux Relay switch positions. To determine the actual cycles that the gate operator has run (in thousands), set all three Aux Relay switches to the ON setting for Aux Relay 1. The Expansion Board's 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED blinking 1000's, 2 LED blinking 10,000's, 3 LED blinking 100,000's, and simultaneously all three LED's blink 1,000,000's (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is 163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset or changed. If under 1,000 cycles the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off. NOTE: The expansion board will flash the cycle count 3 times then all the LEDs will turn on solid for 10 seconds then turn off. RED/GREEN LIGHT FUNCTIONALITY Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2. GATE STATE AUX RELAY 1 SWITCHES 1 OFF 2 OFF 3 OFF AUX RELAY 2 SWITCHES 1 ON 2 ON 3 ON Closed Red light OFF* Green light OFF Opening Red light ON/Flash Green light OFF Open Red light OFF Green light ON Closing Red light ON/Flash Green light OFF Defined Mid Stop n/a n/a Undefined Mid Stop Red light ON Green light OFF Timer more than 5 seconds Red light OFF Green light ON Timer less than 5 seconds Red light ON/Flash Green light OFF * For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON Expansion board Control board RED COM GREEN N.O. N.C. Com Com N.C. N.O. EXPANSION BOARD N.O. N.C. Com Com N.C. N.O. RELAY ADAPTER BOARD Red/green light RGL24LY 36