APPENDIX SAMS Wiring with Relays Not Energized SAMS Operation To keep vehicles from rushing the gate, the barrier arm stays in closed position until the gate reaches fully open position then the barrier arm is released to open and allow vehicles to pass. AUX Relay 1 Dual Gate Settings NOTE: We recommend that all accessories, except entrapment protection devices, and board configurations are set on the primary operator. Main control board Accessories FEATURE PRIMARY OPERATOR SECONDARY OPERATOR Timer-to- Set the TTC dial to desired OFF Close setting Bi-Part Delay Switch Synchronized Close: ON Synchronized Close: ON Speed Set the speed control dial on each operator to the desired setting, see page 24 for more details Expansion board ACCESSORY Remote Controls LiftMaster Internet Gateway Garage and Gate Monitor PRIMARY OPERATOR SECONDARY OPERATOR Program remote controls 1 to 50 to the primary operator. Program remote controls 51 to 100 to the secondary operator Program to primary operator. Program to primary operator. FEATURE PRIMARY OPERATOR SECONDARY OPERATOR QUICK CLOSE Switch ON OFF ANTI-TAIL Switch ON OFF LOW BATT Switch Battery Fail OPEN: OPEN Battery Fail CLOSE: CLOSE Battery Fail OPEN: OPEN Battery Fail CLOSE: CLOSE AC FAIL OPEN/BATT OPEN Switch OPEN 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

53
SAMS Wiring with Relays Not Energized
SAMS Operation
To keep vehicles from rushing the gate, the barrier arm stays in closed position until the gate reaches fully open position then the barrier arm is released to
open and allow vehicles to pass.
AUX Relay 1
Dual Gate Settings
NOTE:
We recommend that all accessories, except entrapment protection devices, and board configurations are set on the primary operator.
Main control board
FEATURE
PRIMARY OPERATOR
SECONDARY OPERATOR
Timer-to-
Close
Set the TTC dial to desired
setting
OFF
Bi-Part
Delay
Switch
Synchronized Close: ON
Synchronized Close: ON
Speed
Set the speed control dial on each operator to the desired
setting, see
page 24
for more details
Expansion board
FEATURE
PRIMARY OPERATOR
SECONDARY
OPERATOR
QUICK CLOSE Switch
ON
OFF
ANTI-TAIL Switch
ON
OFF
LOW BATT Switch
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
AC FAIL OPEN/BATT
Switch
OPEN
OPEN
Accessories
ACCESSORY
PRIMARY OPERATOR
SECONDARY
OPERATOR
Remote Controls
Program remote
controls 1 to 50 to the
primary operator.
Program remote
controls 51 to 100 to the
secondary operator
LiftMaster Internet
Gateway
Program to primary
operator.
Garage and Gate
Monitor
Program to primary
operator.
APPENDIX