2013 Kawasaki JET SKI Ultra LX Owners Manual - Page 146

2013 Kawasaki JET SKI Ultra LX Manual

Page 146 highlights

144 MAINTENANCE AND ADJUSTMENTS WARNING Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling. Battery Sulfation A common cause of battery failure is sulfation. Sulfation occurs when the battery is left in a discharged condition for an extended time. Sulfate is a normal by product of the chemical reactions within a battery. But when continuous discharge allows the sulfate to crystallize in the cells, the battery plates become permanently damaged and will not hold a charge. Battery failure due to salvation is not warrantable. Battery Maintenance It is the owner's responsibility to keep the battery fully charged. Failure to do so can lead to battery failure and leave you stranded. If you are riding your watercraft infrequently, inspect the battery voltage weekly using a voltmeter. If it drops below 12.6 volts, the battery should be charged using an appropriate charger (check with our Kawasaki dealer or visit buy Kawasaki. com) at a rate (amperage × hours) that is indicated on the battery. If it is not possible to read the rate, charge the battery at an amperage that is about 1/10th of the battery capacity. If you will not be using your watercraft for longer than two weeks, the battery should be charged using an appropriate charger. Do not use an automotive -type quick charger that may overcharge the battery and damage it. NOTE żLeaving the battery connected causes the electrical components (clock etc) to make the battery discharged, resulting the over discharge of the battery. In this case, the repair or replacement of the battery is not included in the warranty. If you do not drive for four weeks or more, disconnect the battery from the vehicle. j Kawasaki-recommended chargers are: Battery Mate 150-9 OptiMate 4 Yuasa MB-2040/2060 Christie C10122S If the above chargers are not available, use equivalent one. For more details, ask your Kawasaki dealer. Battery Charging the battery from the watercraft (See Bat• Remove tery Removal). the battery charge timer to the position indi• Set cated by the tester. the charging and checking steps of the • Following battery charger, charge the battery.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169

144
MAINTENANCE AND ADJUSTMENTS
j
WARNING
Battery posts, terminals and related acces-
sories contain lead and lead compounds,
chemicals known to the State of California to
cause cancer and reproductive harm. Wash
hands after handling.
Battery Sulfation
A common cause of battery failure is sulfation.
Sulfation occurs when the battery is left in a dis-
charged condition for an extended time. Sulfate is a
normal by product of the chemical reactions within a
battery. But when continuous discharge allows the
sulfate to crystallize in the cells, the battery plates
become permanently damaged and will not hold a
charge. Battery failure due to salvation is not war-
rantable.
Battery Maintenance
It is the owner’s responsibility to keep the battery
fully charged.
Failure to do so can lead to battery
failure and leave you stranded.
If you are riding your watercraft infrequently, in-
spect the battery voltage weekly using a voltmeter.
If it drops below 12.6 volts, the battery should be
charged using an appropriate charger (check with
our Kawasaki dealer or visit buy Kawasaki. com) at
a rate (amperage × hours) that is indicated on the
battery. If it is not possible to read the rate, charge
the battery at an amperage that is about 1/10th of
the battery capacity.
If you will not be using your watercraft for longer
than two weeks, the battery should be charged using
an appropriate charger. Do not use an automotive
-type quick charger that may overcharge the battery
and damage it.
NOTE
°
Leaving the battery connected causes the electri-
cal components (clock etc) to make the battery dis-
charged, resulting the over discharge of the bat-
tery. In this case, the repair or replacement of the
battery is not included in the warranty. If you do
not drive for four weeks or more, disconnect the
battery from the vehicle.
Kawasaki-recommended chargers are:
Battery Mate 150-9
OptiMate 4
Yuasa MB-2040/2060
Christie C10122S
If the above chargers are not available, use equiv-
alent one.
For more details, ask your Kawasaki dealer.
Battery Charging
Remove the battery from the watercraft (See Bat-
tery Removal).
Set the battery charge timer to the position indi-
cated by the tester.
Following the charging and checking steps of the
battery charger, charge the battery.