Kenwood TS-570D User Manual - Page 81

Reading Command Tables, Computer Control Command Tables

Page 81 highlights

READING COMMAND TABLES w u i o !0 q AC ANTENNA TUNER CONTROL Function Antenna Tuner THRU/IN -LINE, and tuning e START/CANCEL Parameter Format Parameter function P1 30 TUNE THRU/IN (Answer Only) P2 30 TUNE THRU/IN Input Read Set r 1 2 3 4 5 6 7 8 9 10 11 12 13 14 P3 1 TUNE OFF/ON A C P2 P3 ; Note: t 1 2 3 4 5 6 7 8 9 10 11 12 13 14 P1 is used for Answer only. Tuning cannot be started if P2 is in AC ; the THRU state (If P2="0", selecting Output Answer 1 2 3 4 5 6 7 8 9 10 11 12 13 14 "1" for P3 does not start tuning). y A C P1 P2 P3 ; P1: RX THRU/IN P2: TX THRU/IN APPENDIX ● q Command w Name e Function of the command r The format of the Set command is shown. When oblique lines are drawn in the 1st and 2nd columns, there is no Set command. t The format of the command for reading the transceiver's current status is shown. When oblique lines are drawn in the 1st and 2nd columns, there is no Read command. y The format of the command output from the transceiver is shown. When oblique lines are drawn in the 1st and 2nd columns, there is no Answer command. u The number of command digits is shown. i Corresponds to the parameter of the command format. o Corresponds to the Format number in the Parameter Table. For the parameter formats, refer to the Parameter Table {page 73}. !0 Indicates the function of the parameter. COMPUTER CONTROL COMMAND TABLES Note: Parameters that have a Parameter Function of "NOT USED" are not supported by this transceiver. Any character except the ASCII control codes (00 to 1Fh) and the terminator (;) may be entered for those parameters. Function Input Read Set Output Answer AC ANTENNA TUNER CONTROL Antenna Tuner THRU/IN -LINE, and tuning START/CANCEL Parameter Format Parameter function P1 30 TUNE THRU/IN (Answer Only) P2 30 TUNE THRU/IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 P3 1 TUNE OFF/ON A C P2 P3 ; Note: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 P1 is used for Answer only. Tuning cannot be started if P2 is in AC ; the THRU state (If P2="0", selecting 1 2 3 4 5 6 7 8 9 10 11 12 13 14 "1" for P3 does not start tuning). P1: RX THRU/IN A C P1 P2 P3 ; P2: TX THRU/IN Output Answer Input Read Set Function AI AUTO INFORMATION Auto information OFF/ON Parameter Format Parameter function P1 32 AI NUMBER Note: For other commands, controls whether changing a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 parameter will or will not trigger the A I P1 ; corresponding Answer command to be output. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Ex: For IF, the Answer command is AI ; output if the step frequency or RIT/XIT frequency is changed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Switching the transceiver ON A I P1 ; restores "0". AG AF GAIN Sets or reads AF gain. Parameter Format Parameter function P1 31 AF GAIN AN ANTENNA NUMBER Selects antenna connector ANT 1/ ANT 2. Parameter Format Parameter function P1 33 ANTENNA NUMBER Function Function Input Read Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A G P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 AG ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A G P1 ; Input Read Set 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A N P1 ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 AN ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 A N P1 ; Output Answer 75 Output Answer

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89

75
APPENDIX
READING COMMAND TABLES
q
Command
w
Name
e
Function of the command
r
The format of the Set command is shown.
When oblique lines are drawn in the 1st and 2nd columns, there is no Set
command.
t
The format of the command for reading the transceiver°s current status is shown.
When oblique lines are drawn in
the 1st and 2nd columns, there is no Read command.
y
The format of the command output from the transceiver is shown.
When oblique lines are drawn in the 1st and 2nd
columns, there is no Answer command.
u
The number of command digits is shown.
i
Corresponds to the parameter of the command format.
o
Corresponds to the Format number in the Parameter Table.
For the parameter formats, refer to the Parameter
Table {page 73}.
!
0
Indicates the function of the parameter.
COMPUTER CONTROL COMMAND TABLES
Note:
Parameters that have a Parameter Function of “NOT USED” are not supported by this transceiver.
Any character except the ASCII control
codes (00 to 1Fh) and the terminator (;) may be entered for those parameters.
Note:
P1 is used for Answer only.
Tuning cannot be started if P2 is in
the THRU state (If P2="0", selecting
"1" for P3 does not start tuning).
P1: RX THRU/IN
P2: TX THRU/IN
1
2
Parameter
Format
Parameter function
3
4
5
6
7
8
9
10
11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9
10
11 12 13 14
1
2
3
4
5
6
7
8
9
10
11 12 13 14
AC
ANTENNA TUNER CONTROL
Antenna Tuner THRU/IN -LINE, and tuning
START/CANCEL
A
C
P2 P3
A
C
P1 P2 P3
A
C
;
;
;
P1
P2
P3
30
30
1
TUNE THRU/IN
(Answer Only)
TUNE THRU/IN
TUNE OFF/ON
u
i
o
!0
w
r
t
y
e
q
1
2
Parameter
Format
Parameter function
3
4
5
6
7
8
9
10
11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9
10
11 12 13 14
1
2
3
4
5
6
7
8
9
10
11 12 13 14
AI
AUTO INFORMATION
Auto information OFF/ON
A
I
P1
A
I
P1
;
A
I
;
;
P1
32
AI NUMBER
Note:
For other commands,
controls whether changing a
parameter will or will not trigger the
corresponding Answer command
to be output.
Ex:
For IF, the Answer command is
output if the step frequency or
RIT/XIT frequency is changed.
Switching the transceiver ON
restores "0".
Note:
P1 is used for Answer only.
Tuning cannot be started if P2 is in
the THRU state (If P2="0", selecting
"1" for P3 does not start tuning).
P1: RX THRU/IN
P2: TX THRU/IN
1
2
Parameter
Format
Parameter function
3
4
5
6
7
8
9
10
11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9
10
11 12 13 14
1
2
3
4
5
6
7
8
9
10
11 12 13 14
AC
ANTENNA TUNER CONTROL
Antenna Tuner THRU/IN -LINE, and tuning
START/CANCEL
A
C
P2 P3
A
C
P1 P2 P3
A
C
;
;
;
P1
P2
P3
30
30
1
TUNE THRU/IN
(Answer Only)
TUNE THRU/IN
TUNE OFF/ON
P1
33
ANTENNA
NUMBER
1
2
Parameter
Format
Parameter function
3
4
5
6
7
8
9
10
11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9
10
11 12 13 14
1
2
3
4
5
6
7
8
9
10
11 12 13 14
AN
ANTENNA NUMBER
Selects antenna connector ANT 1/ ANT 2.
A
N
P1
A
N
P1
;
A
N
;
;
P1
31
AF GAIN
1
2
Parameter
Format
Parameter function
3
4
5
6
7
8
9
10
11 12 13 14
Input
Function
Output
Set
Read
Answer
1
2
3
4
5
6
7
8
9
10
11 12 13 14
1
2
3
4
5
6
7
8
9
10
11 12 13 14
AG
AF GAIN
Sets or reads AF gain.
P1
A
G
;
A
G
;
A
G
P1
;