Lantronix MatchPort b/g MatchPort b/g - User Guide - Page 62

Domain Name, Recipients, Triggers, Trigger input2 [A/I/X] X ?

Page 62 highlights

5: Configuration via Serial Mode or Telnet Port Mail Server Enter the IP address of the mail server. Enter each 3-digit section and press Enter between sections. The current value displays in parentheses. Mail Server (0.0.0.0) ? (000) .(000) .(000) .(000) Unit Name Enter the username used by the MatchPort to send email messages. The current value displays in parentheses. Note: Do not use spaces in the name. Unit name () ? _ Domain Name Enter the email server's domain name. The current value displays in parentheses. Domain name () ? _ Recipients Enter the full email address of up to two trigger email recipients. The current value displays in parentheses. Recipient 1 () ? _ Recipient 2 () ? _ Triggers A trigger event occurs when the unit receives the specified trigger input because of a specified combination of conditions on the configurable pins. Enable serial trigger input (N) ? Trigger input1 [A/I/X] (X) ? Trigger input2 [A/I/X] (X) ? Trigger input3 [A/I/X] (X) ? Message () ? Priority (L) ? Minimum notification interval (1 s) ? Re-notification interval (0 s) ? To change the configurable pins' settings, send setup records to Port 77FE. Enable serial trigger Select (Y) Yes to enable serial trigger inputs. input MatchPort User Guide 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

5: Configuration via Serial Mode or Telnet Port
Mail Server
Enter the IP address of the mail server. Enter each 3-digit section and press
Enter
between sections. The current value displays in parentheses.
Mail Server (0.0.0.0) ? (000) .(000) .(000) .(000)
Unit Name
Enter the username used by the MatchPort to send email messages. The current
value displays in parentheses.
Note:
Do not use spaces in the name.
Unit name () ? _
Domain Name
Enter the email server’s domain name. The current value displays in parentheses.
Domain name () ? _
Recipients
Enter the full email address of up to two trigger email recipients. The current value
displays in parentheses.
Recipient 1 () ? _
Recipient 2 () ? _
Triggers
A trigger event occurs when the unit receives the specified trigger input because of a
specified combination of conditions on the configurable pins.
Enable serial trigger input (N) ?
Trigger input1 [A/I/X] (X) ?
Trigger input2 [A/I/X] (X) ?
Trigger input3 [A/I/X] (X) ?
Message () ?
Priority (L) ?
Minimum notification interval (1 s) ?
Re-notification interval (0 s) ?
To change the configurable pins’ settings, send setup records to Port 77FE.
Enable serial trigger
input
Select (
Y
) Yes to enable serial trigger inputs.
MatchPort User Guide