5: Configuration via Serial Mode or Telnet Port Y (Yes) auto increment the source port. The MatchPort increments the port number used with each new connection. Remote IP Address This is the destination IP address used with an outgoing connection. Remote IP Address : ( 0) ( 0) ( 0) ( 0)_ Note: This option is not displayed when Hostlist is enabled from the ConnectMode prompt (see page 49 for more information). Remote Port Set the remote TCP port number for the unit to make outgoing connections. This parameter defines the port number on the target host to which a connection is attempted. Remote Port ( 0) ? _ To connect an ASCII terminal to a host using the unit for login purposes, use the remote port number 23 (Internet standard port number for Telnet services). Note: This option does not display when Hostlist is enabled from the ConnectMode prompt (see page 49 for more information). DisConnMode Disconnect Mode (DisConnMode) determines the conditions under which the unit will cause a network connection to terminate. The current value displays in parentheses. DisConnMode ( 0) ? _ Note: All bit positions in the table that are blank represent "don't care" bits for that particular option, which can be set to either a 0 or a 1 value. The following table displays the available input options: Disconnect Mode Option 7 6 Disconnect when Modem Control In is not asserted(6) 1 5 4 3 2 1 0 Ignore Modem Control In 0 Telnet Com Port Cntrl and terminal type setup (1) 1 Channel (port) password (2) 1 Hard disconnect (3) 0 Disable hard disconnect State LED off with connection (4) 1 1 MatchPort User Guide 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

5: Configuration via Serial Mode or Telnet Port
Y
(Yes) auto increment the source port. The MatchPort increments the port number
used with each new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : ( 0) ( 0) ( 0) ( 0)_
Note:
This option is not displayed when Hostlist is enabled from the
ConnectMode
prompt (see page 49 for more information).
Remote Port
Set the remote TCP port number for the unit to make outgoing connections. This
parameter defines the port number on the target host to which a connection is
attempted.
Remote Port ( 0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, use the
remote port number 23 (Internet standard port number for Telnet services).
Note:
This option does not display when
Hostlist
is enabled from the
ConnectMode
prompt (see page 49 for more information).
DisConnMode
Disconnect Mode (DisConnMode) determines the conditions under which the unit will
cause a network connection to terminate. The current value displays in parentheses.
DisConnMode ( 0) ? _
Note:
All bit positions in the table that are blank represent "don't care" bits for
that particular option, which can be set to either a 0 or a 1 value.
The following table displays the available input options:
Disconnect Mode Option
7
6
5
4
3
2
1
0
Disconnect when Modem Control In is not asserted
(6)
1
Ignore Modem Control In
0
Telnet Com Port Cntrl and terminal type setup
(1)
1
Channel (port) password
(2)
1
Hard disconnect
(3)
0
Disable hard disconnect
1
State LED off with connection
(4)
1