Campbell Scientific AVW200 AVW200-series Vibrating Wire Interfaces - Page 38

Data Monitor, Multiplexer Type, Begin Frequency, Excitation

Page 38 highlights

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Multiplexer Type-choose the appropriate multiplexer. The default multiplexer type is the AM16/32B. Begin Frequency-if using RS-232 (terminal commands) or SDI-12, enter the sensor manufacturer's recommendation for the begin frequency. End Frequency-if using RS-232 (terminal commands) or SDI-12, enter the sensor manufacturer's recommendation for the end frequency. Excitation-if using RS-232 (terminal commands) or SDI-12, choose either "5 Volts Peak-Peak" or "12 Volts Peak-Peak" excitation. Use the sensor manufacturer's recommendation for the excitation. Once the settings have been defined, press Apply to save the changes to the AVW200. 5.3 Data Monitor The Data Monitor tab in DevConfig can display either the Public Table or Status Table. The public table displays the current sensor measurement values as well as the current settings (see FIGURE 5-4). FIGURE 5-4. Data Display/Public Table in DevConfig 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules
Multiplexer Type
—choose the appropriate multiplexer.
The default
multiplexer type is the AM16/32B.
Begin Frequency
—if using RS-232 (terminal commands) or SDI-12, enter the
sensor manufacturer’s recommendation for the begin frequency.
End Frequency
—if using RS-232 (terminal commands) or SDI-12, enter the
sensor manufacturer’s recommendation for the end frequency.
Excitation
—if using RS-232 (terminal commands) or SDI-12, choose either
“5 Volts Peak-Peak” or “12 Volts Peak-Peak” excitation.
Use the sensor
manufacturer’s recommendation for the excitation.
Once the settings have been defined, press Apply to save the changes to the
AVW200.
5.3
Data Monitor
The Data Monitor tab in DevConfig can display either the Public Table or
Status Table. The public table displays the current sensor measurement values
as well as the current settings (see FIGURE 5-4).
FIGURE 5-4.
Data Display/Public Table in DevConfig
30