Campbell Scientific AVW200 AVW200-series Vibrating Wire Interfaces - Page 25
Multiplexers Controlled by Datalogger, 3.3.1 SDI-12 Communication
View all Campbell Scientific AVW200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules For example, the following AVW200() instructions can be used to control the multiplexers: AVW200(Data1(),ComSDC7,200,200,mux1(1,1),1,1,16,450,3000,2,_60HZ,1,0) AVW200(Data2(),ComSDC7,200,200,mux2(1,1),2,1,16,450,3000,2,_60HZ,1,0) Where, RF401 = configured for SDC7 Each multiplexer has 16 sensors connected to it. Begin Frequency = 450 End frequency = 3000 Excitation voltage = 12 V peak to peak (option 2) Read more! A thorough description of the AVW200() instruction and its parameters is provided in Section 6.1. A complete example program that controls two multiplexers is included in Appendix H.1.2. 3.3 Multiplexers Controlled by Datalogger 3.3.1 SDI-12 Communication AVW200 Power Supply Sensors Multiplexer Datalogger NOTES Cable that Comes with Sensor CABLE4CBL Cable CABLE3CBL Cable 19246 Power Cable For this example configuration, SDI-12 is used to measure the vibrating wire sensors. The vibrating wire sensors are attached to multiplexers, which are controlled by the datalogger. (1) When using SDI-12, multiplexers have to be controlled by the datalogger. (2) SDI-12 is the only option available for our CR10X, CR23X, and CR5000 dataloggers. (3) SDI-12 is the only option available for non-Campbell Scientific dataloggers. 17