Datalogger Wiring (Direct Connection)

Page 28 highlights

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules Connects to earth ground via an 8 AWG wire when not directly connected to a datalogger Connects to a power source via 19246 power cable Indicates AVW200 is connected to a power source FIGURE 4-2. Ground Lug and Power Connectors on the AVW200 4.3 Datalogger Wiring (Direct Connection) There are three options for connecting the AVW200 directly to the datalogger (see TABLE 4-1); the cable is ordered as a common accessory. TABLE 4-1. Datalogger to AVW200 Cable Options Communication Protocol PakBus (direct RS-232 connection) PakBus (direct RS-232 connection) SDI-12 Cable Used 18663 Null Modem Cable 17855 or SC110's DTE Cable (pigtail to DB9; see TABLE 4-2) CABLE3CBL-L Cable Datalogger Port for Cable Attachment CR800, CR850 RS-232 CR1000, CR3000 RS-232 CR5000 CR10X CR23X N/A N/A N/A Control port pair (C1/C2 or C3/C4) C1 or C3 and G Control port pair (C1/C2, C3/C4, C5/C6, or C7/C8) C1, C3, C5, or C7 and G N/A SDI12 and G N/A N/A C1 through C8 and G C5 through C8 and G AVW200 Port for Cable Attachment RS-232 RS-232 C1 and G 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules
FIGURE 4-2.
Ground Lug and Power Connectors on the AVW200
4.3
Datalogger Wiring (Direct Connection)
There are three options for connecting the AVW200 directly to the datalogger
(see TABLE 4-1); the cable is ordered as a common accessory.
TABLE 4-1.
Datalogger to AVW200 Cable Options
Communication
Protocol
Cable Used
Datalogger Port for Cable Attachment
AVW200
Port for
Cable
Attachment
CR800,
CR850
CR1000,
CR3000
CR5000
CR10X
CR23X
PakBus (direct
RS-232
connection)
18663 Null
Modem Cable
RS-232
RS-232
N/A
N/A
N/A
RS-232
PakBus (direct
RS-232
connection)
17855 or
SC110’s DTE
Cable (pigtail to
DB9; see
TABLE 4-2)
Control
port pair
(C1/C2
or
C3/C4)
Control
port pair
(C1/C2,
C3/C4,
C5/C6, or
C7/C8)
N/A
N/A
N/A
RS-232
SDI-12
CABLE3CBL-L
Cable
C1 or
C3
and G
C1, C3,
C5,
or C7
and G
SDI12
and
G
C1
through
C8 and
G
C5
through
C8 and
G
C1 and G
Connects to a power source via
19246 power cable
Connects to earth ground via an 8 AWG wire
when not directly connected to a datalogger
Indicates AVW200 is
connected to a power source
20