Adaptec 5405 User Guide - Page 100

Apply, Select the disk drives you want to update, then click

Page 100 highlights

Chapter 8: Maintaining Physical Devices ● 100 4 In the wizard, select the image file you want, choose the packet size (in bytes) from the drop-down list, then click Next. Note: For SATA drives, the packet size must be a multiple of 512. 5 Select the disk drives you want to update, then click Next. Note: For SAS drives with "Mode 6" support, select Save Later to use the new firmware once, during the current session, and to revert to the previous firmware the next time the drive is started. 6 Review the update summary, then click Apply.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187

Chapter 8: Maintaining Physical Devices
100
4
In the wizard, select the image file you want, choose the packet size (in bytes) from the
drop-down list, then click
Next
.
Note:
For SATA drives, the packet size must be a multiple of 512.
5
Select the disk drives you want to update, then click
Next
.
Note:
For SAS drives with “Mode 6” support, select
Save Later
to use the new firmware once,
during the current session, and to revert to the previous firmware the next time the drive is
started.
6
Review the update summary, then click
Apply
.