LiftMaster CAPXLV2 Installation Manual - English French Spanish - Page 6

Door of Control Board Overview, INPUT/OUTPUT, TYPE CONFIGURABLE, USED

Page 6 highlights

INTRODUCTION ACCOUNT SETUP POWER NETWORK/MOUNTING ACCESS CONTROL Door of Control Board Overview ThINe TCARPOXDLVU2ChTasIOa NcombinatioAnCoCf aOccUeNssTcoSnEtrTolUinPputs/ouPtpOuWts EonRthe doNorEoTf WcoOntrRoKl b/MoaOrdU(sN) tThaINt wGork in AcoCnCjuEncStiSonCtoOcNonTtRroOl uLp to 4 access points each, so CAPXLV2 can control up to 8 access points in total. DO NOT use the Wiegand 12V power output port to power anything except the Wiegand proximity readers. INTRODUCTION ACCOUNT SETUP POWER Wiegand 1 Wiegand 2 NETWORK/MOUNTING ACCESS CONTROL Wiegand 3 Wiegand 4 Monitored Input 1 INTRODUCTION Monitored Input 2 Relay 1 Relay 2 WiegIaNndTRODUCTION Output ACCOUNT SETUP Monitored Input 3POWER Monitored Input 5 NETWORK/MOUNTING Monitored Input 4 Monitored Input 6 Relay 3 Relay 5 Monitored ACCESS CONTInRpuOt 7L Monitored Input 8 Relay 7 Relay 4 Relay 6 ACCOUNT SETUP POWER WiegaNndETWORK/MOUNTING Output Relay 8 ACCESS CONTROL INPUT/OUTPUT Monitored Inputs Relay Wiegand Input Wiegand Output NOTE: Monitored inputs can operate in any of the following configurations: Rex, knox box, or status. TYPE (CONFIGURABLE) REX (Request to Exit) Knox Box Status USED FOR External Free Exit Loop Detectors, REX Buttons, and Proximity Sensors In the case of an emergency (medical or fire), the Fire Rescue Department is able to gain entry. Door sensors detecting when door is ajar. Supervised Gate Operators detecting when failed to close. Supervised Gate Operators detecting when failed to open. Gate Operator, Door Strikes, Alarm Shunt, Maglocks, and Lights (for control only - power to be provided by external supply) Proximity Readers (Wiegand 12Vdc power is for readers only, do not use to power other external devices). Access grant activity for integration with other access systems NOTE: Only the 26-bit Wiegand protocol and OSDP protocol are compatible in UL installations. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

6
ACCOUNT SETUP
NETWORK/MOUNTING
POWER
ACCESS CONTROL
INTRODUCTION
Door of Control Board Overview
The CAPXLV2 has a combination of access control inputs/outputs on the door of control board(s) that work in conjunction to control up
to 4 access points each, so CAPXLV2 can control up to 8 access points in total.
INPUT/OUTPUT
TYPE (CONFIGURABLE)
USED FOR
Monitored Inputs
REX
(Request to Exit)
External Free Exit Loop Detectors, REX Buttons, and Proximity Sensors
Knox Box
In the case of an emergency (medical or fire), the Fire Rescue Department
is able to gain entry.
Status
Door sensors detecting when door is ajar.
Supervised Gate Operators detecting when failed to close.
Supervised Gate Operators detecting when failed to open.
Relay
Gate Operator, Door Strikes, Alarm Shunt, Maglocks, and Lights (for
control only - power to be provided by external supply)
Wiegand Input
Proximity Readers (Wiegand 12Vdc power is for readers only, do not use
to power other external devices).
Wiegand Output
Access grant activity for integration with other access systems
Wiegand 1
Wiegand 2
Wiegand 3
Wiegand 4
Monitored
Input 5
Monitored
Input 6
Monitored
Input 3
Monitored
Input 4
Relay 1
Relay 3
Relay 2
Relay 5
Relay 6
Relay 4
Relay 7
Relay 8
Monitored
Input 7
Monitored
Input 8
Monitored
Input 1
Monitored
Input 2
Wiegand
Output
Wiegand
Output
NOTE:
Only the 26-bit Wiegand protocol and OSDP protocol are compatible in UL installations.
DO NOT use the Wiegand 12V power output port to power
anything except the Wiegand proximity readers.
NOTE:
Monitored inputs can operate in
any of the following configurations: Rex,