LiftMaster CAPXLV2 Installation Manual - English French Spanish - Page 15

Connect Power, Using A Dc Power Supply, Wire Specification, Maximum Run Distance

Page 15 highlights

INTRODUCTION ACCOUNT SETUP POWER NETWORK/MOUNTING ACCESS CONTROL 5 Connect Power UISNINTGRAODDCUPCOTWIEORNSUPPLY:ACCOUNT SETUP USING PoE (POWER OVER ETHERNET): Connect Ethernet cable to the LAN/PoE connection on the main POWERboard.NETWORK/MOUNTING ACCESS CONTROL The outlet for the CAPXLV2 MUST be an external dedicated 120 Vac outlet. Refer to the table below for maximum wire run distances. This outlet should be wired back to its own 10 Amp minimum circuit breaker. INTRODUCTION WIRE SPECIFICATION 14 AWG ACCOUNT SETUP POWER MAXIMUM RUN DISTANCE Up to 300 feet (91.4 m) Ethernet Input NETWORK/MOUNTING ACCESS CONTROL 16 AWG Up to 200 feet (60.9 m) 18 AWG Up to 100 feet (30.4 m) 1. Connect 14-18 AWG wire to the stripped secondary DC output wires on the power supply. Black is negative and red is positive. 2. Remove the PWR INPUT terminal block from the Power/ Internet Board. 3. Connect the power supply wires to the PWR INPUT terminal block (red to +24V and black to GND). Reattach the terminal block to the Power/Internet Board. 4. Plug the power supply into a 120 Vac outlet after all connections have been made. PoE Injector 120 Vac Dedicated Outlet  NOTE: The green LED on the door of control board will blink and the green LED on the Power/Internet Board will light solid when powered up. The CAPXLV2 will display the LiftMaster logo while booting up. When boot up is complete, the user interface will appear. 5. Close the CAPXLV2 door. Dedicated 10 Amp Minimum Circuit • DO NOT use ANY power supply other than those supplied with your CAPXLV2. • Use the PoE injector or router/switch with PoE PSE capability that complies with 802.3bt (Type 3 four wire class 5 compatible) and UL294 with output power as 36-55V and 45 W(Max) per port. • DO NOT power electronic strikes and latches with the same power supply used to power the access control panel; doing so will cause DAMAGE to the CAPXLV2. Use ONLY a UL listed burglar alarm or access control system to power electronic strikes and latches. POWER INPUT Power/Internet Board When the power supply (low voltage) wiring leaves the enclosure, the wire must be rated for wet and damp locations. High voltage wiring must be run in a separate conduit from low voltage wiring. Only the power supply and its input/output wire may be within this enclosure. Power Supply 120 Vac Dedicated Outlet NOTE: If the power supply is installed outdoors, the power supply must have its own approved NEMA 4 Rated weatherproof electrical enclosure. Use conduit from the power supply enclosure to the controller enclosure. • DO NOT connect the power supply or PoE injector to a switched outlet or otherwise controlled AC outlet. • DO NOT connect the power supply to the 120 Vac outlet until ALL wiring is completed. • DO NOT connect the PoE enabled RJ45 Ethernet cable until ALL wiring is connected, if PoE is used. • Install the transient noise suppression device (MOV) supplied with the CAPXLV2 for AC powered devices and Diode for DC powered devices. • DO NOT connect the 24V power supply and POE power supply to the device at the same time. • If the power supply has a ground wire, then it must be wired to the GND terminal block to ensure effective grounding. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

15
Connect Power
5
DO NOT use ANY power supply other than those supplied
with your CAPXLV2.
Use the PoE injector or router/switch with PoE PSE capability
that complies with 802.3bt (Type 3 four wire class 5
compatible) and UL294 with output power as 36-55V and 45
W(Max) per port.
DO NOT power electronic strikes and latches with the same
power supply used to power the access control panel; doing
so will cause DAMAGE to the CAPXLV2. Use ONLY a UL
listed burglar alarm or access control system to power
electronic strikes and latches.
DO NOT connect the power supply or PoE injector to a
switched outlet or otherwise controlled AC outlet.
DO NOT connect the power supply to the 120 Vac outlet until
ALL wiring is completed.
DO NOT connect the PoE enabled RJ45 Ethernet cable until
ALL wiring is connected, if PoE is used.
Install the transient noise suppression device (MOV) supplied
with the CAPXLV2 for AC powered devices and Diode for DC
powered devices.
DO NOT connect the 24V power supply and POE power
supply to the device at the same time.
If the power supply has a ground wire, then it must be wired
to the GND terminal block to ensure effective grounding.
USING A DC POWER SUPPLY:
The outlet for the CAPXLV2 MUST be an external dedicated
120 Vac outlet. Refer to the table below for maximum wire run
distances. This outlet should be wired back to its own 10 Amp
minimum circuit breaker.
1.
Connect 14-18 AWG wire to the stripped secondary DC
output wires on the power supply. Black is negative and red is
positive.
2.
Remove the PWR INPUT terminal block from the Power/
Internet Board.
3.
Connect the power supply wires to the PWR INPUT terminal
block (red to +24V and black to GND). Reattach the terminal
block to the Power/Internet Board.
4.
Plug the power supply into a 120 Vac outlet after all
connections have been made.
NOTE:
The green LED on the door of control board will
blink and the green LED on the Power/Internet Board will
light solid when powered up. The CAPXLV2 will display
the LiftMaster logo while booting up. When boot up is
complete, the user interface will appear.
5.
Close the CAPXLV2 door.
INTRODUCTION
ACCESS CONTROL
ACCOUNT SETUP
NETWORK/MOUNTING
POWER
WIRE SPECIFICATION
MAXIMUM RUN DISTANCE
14 AWG
Up to 300 feet (91.4 m)
16 AWG
Up to 200 feet (60.9 m)
18 AWG
Up to 100 feet (30.4 m)
USING PoE (POWER OVER ETHERNET):
Connect Ethernet cable to the LAN/PoE connection on the main
board.
When the power supply
(low voltage) wiring
leaves the enclosure, the
wire must be rated for wet
and damp locations.
High voltage wiring must
be run in a separate
conduit from low voltage
wiring.
NOTE:
If the power supply is installed outdoors,
the power supply must have its own approved
NEMA 4 Rated weatherproof electrical enclosure.
Use conduit from the power supply enclosure to
the controller enclosure.
Only the power supply
and its input/output
wire may be within
this enclosure.
Power Supply
120 Vac
Dedicated Outlet
Dedicated 10 Amp
Minimum Circuit
POWER INPUT
Power/Internet Board
Ethernet
Input
PoE Injector
120 Vac
Dedicated Outlet