LiftMaster CAPXLV2 Installation Manual - English French Spanish - Page 17
ACCESS CONTROL, Gate Access (Wired), Disconnect power BEFORE making electrical connections.
View all LiftMaster CAPXLV2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
INTRODUCTION ACCOUNT SETUP POWER NETWORK/MOUNTING ACCESS CONTROL Gate Access (Wired) Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can be wired to Relay 1, 2, 3, or 4 on the Door of Control Board. LiftMaster® Security+ 2.0® gate operators can also be programmed to communicate wirelessly instead of using a wired connection (refer to the following page). Input and output port functions on CAPXLV2 can be configured via the myQ Community web portal. Below is an example use case of connections to various external devices. 12Vdc - red GROUND - black DATA 0 - green DATA 1 - white GREEN LED - orange RED LED - brown RFID ANTENNA with Wiegand output WIEGAND KEYPAD READER NOTE: The length of the unshielded wires should be kept to a minimum to avoid electrical noise. OR Power for RFID ANTENNA (Not Provided) DO NOT use the power NOTE: For the LiftMaster RFID reader, supply for the controller follow the wiring diagram in the manual for the LMSC1000. STATUS (Not applicable for wireless gate operator connections.) GATE OPERATOR (connect to Aux Closed Limit switch refer to gate operator manual) EOL (End of Line) Resistor (1k ohm) OR NOTE: For KPR2000 keypad, wire the pink and black (ground) wires together. REQUEST TO EXIT EXTERNAL FREE EXIT PUSH LOOP DETECTOR BUTTON OR NOTE: When wiring a LiftMaster Smart Reader, follow the wiring diagram colors in the Smart Reader install guide. Do not use the color guide here. REQUEST TO EXIT COMMON STATUS NORMALLY OPEN PRIMARY RELAY GATE OPERATOR LiftMaster® Security+ 2.0® gate operators can be programmed to communicate wirelessly instead of using a wired connection. Refer to the following page. EXIT COMMON COMMON NORMALLY OPEN COMMON NORMALLY CLOSED *AUXILIARY RELAY MAGLOCK Use 18-22 AWG For AC Power: Install a Siemens S10K30MOV (Metal Oxide Varistor) (provided) or equivalent NORMALLY CLOSED For DC Power: Install a 1N4005 diode or equivalent - COMMON + Power for Maglock (Not Provided) DO NOT use the power supply for the controller AUXILIARY RELAY Low Voltage Power Supply Isolation Relay LIGHT LOAD LINE NEUTRAL NOTE: DO NOT run high voltage power within OR the CAPXL enclosure. ALARM BYPASS COMMUN NORMALLY OPEN 17 * NOTE: MAGLOCK and ALARM BYPASS not evaluated by UL.