LiftMaster CAPXLV2 Installation Manual - English French Spanish - Page 18

Gate Access (Wireless

Page 18 highlights

INTRODUCTION ACCOUNT SETUP POWER NETWORK/MOUNTING ACCESS CONTROL Gate Access (Wireless) The CAPXLV2 can communicate wirelessly to LiftMaster® UL325 gate operators to send open commands, monitor gate position, and send email notifications if an error occurs in the operator (email notifications are configured in myQ®). Up to 8 gate operators can be paired with the CAPXLV2 - one for each relay. If using dual gates, program the CAPXLV2 to the primary operator. NOTE: Use of this feature requires the optional Passport antenna kit. 1 Enter Admin Mode Press the 3 dots in the upper right corner of the CAPXLV2 display and enter the Admin Code 2 Select Outputs and Relay Select the Outputs tab. Then select the desired relay on the lefthand side (1 through 8). 3 Press LEARN button on gate operator Press and release the LEARN button on the primary operator. The green XMITTER LED will light. NOTE: The operator will time out of programming mode after 180 seconds. 4 Press LEARN button on gate operator again Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light. DIAGNOSTICS DIAGNOSTICS 5 Select LEARN on display Select the LEARN button on the display and the Learn button will go from blue to red. The gate operator will beep once, CAPXLV2 learn button will change to "Unlearn", and the NETWORK LED on the gate operator will turn off, indicating programming is successful. NOTE: 4 beeps/blinks indicate you are not programming to the primary operator. Reattempt programming from the other operator. 6 Validate Validate functionality by selecting Test Relay on the CAPXLV2 display. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

18
INTRODUCTION
ACCOUNT SETUP
NETWORK/MOUNTING
POWER
ACCESS CONTROL
Gate Access (Wireless)
The CAPXLV2 can communicate wirelessly to LiftMaster
®
UL325 gate operators to send open commands, monitor gate position, and
send email notifications if an error occurs in the operator (email notifications are configured in myQ
®
). Up to 8 gate operators can be
paired with the CAPXLV2 - one for each relay. If using dual gates, program the CAPXLV2 to the primary operator.
NOTE:
Use of this feature requires the optional Passport antenna kit.