2013 Kawasaki MULE 610 4X4 Owners Manual - Page 123
2013 Kawasaki MULE 610 4X4 Manual
Page 123 highlights
MAINTENANCE AND ADJUSTMENT 121 the battery at a rate that is 1/10th of the • Charge battery capacity. For example, the charging rate for a 10 Ah battery would be 1.0 ampere. WARNING Lead is a toxic substance. Battery posts, terminals and related accessories contain lead and lead compounds. Wash hands after handling. NOTICE Do not use a high rate battery charger, as is typically employed at automotive service stations, unless the charging rate can be reduced to the level required for this vehicle's battery. Charging the battery at a rate higher than specified may ruin the battery. Charging at a high rate causes excess heat which can warp the plates and cause internal shorting. Higher-than-normal charging rates also cause the plates to shed active material. Deposits will accumulate, and can cause internal shorting. If the temperature of the electrolyte rises above 45 °C (113 °F) during charging, reduce the charging rate to lower the temperature, and increase charging time proportionately. charging, check the electrolyte level in each • After cell. If the level has fallen, add distilled water to j • • bring it back up to the upper level line. Install the caps on the cells. Install the battery (See Battery Installation).