104 MAINTENANCE AND ADJUSTMENT Belt Drive Torque Converter Air Cleaner A clogged belt drive torque converter air cleaner may cause the torque converter to malfunction. NOTICE A clogged air cleaner may allow dirt and dust to enter the belt drive torque converter causing excessive wear of the inner parts and loss of driving power. The air cleaner elements must be cleaned in accordance with the Periodic Maintenance Chart. In dusty areas, the elements should be cleaned more frequently than the recommended interval. The elements should be replaced if they are damaged. j Element Removal A. Guard Plate B. Air Intake Ducts (2 p.c.s.) C. Clamps D. Quick Rivets (6 p.c.s.) E. Cap the cargo bed and support it with the hook. • Lift the seat. • Raise the guard plate by releasing the two air • Remove intake ducts and the 6 quick rivets. the snaps and remove the air cleaner • Release housing cover from the housing. the air cleaner element out of the housing. • Pull a clean, lint-free towel into the air cleaner • Push housing to keep dirt or other foreign material from entering.