LiftMaster CAPXM Installation Manual - English French Spanish Manufactured Pri - Page 21

Wiegand Output, Postal Lock, Disconnect power BEFORE making electrical connections., And/Or

Page 21 highlights

INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL Wiegand Output Disconnect power BEFORE making electrical connections. The CAPXM offers a Wiegand output capable of 26-bit transmission of the following data: • Success Call with access granted by the resident. The CAPXM will provide a myQ® Business™ specified facility code followed by the Directory Code of the resident that granted access. And/Or • Successful access through Entry Code. The CAPXM will provide a myQ® Business™ specified facility code followed by the successful Entry Code. And/Or • Successful access with a Wiegand credential. The CAPXM will pass along the successful credential Facility Code and ID. Data-0 Ground Data-1 Third Party Access System Wiegand Input (This Device/Reader Must be Listed to UL 294.) DOOR BOARD Postal Lock 1. Remove the wing nut and plug. Discard the wing nut and plug. 2. Remove 4 mounting nuts from studs. 3. Install postal lock using 4 nuts. 4. Cut the factory installed wire tie from the postal lock switch. 5. The postal lock switch is wired from the factory. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

21
Wiegand Output
DOOR BOARD
Third Party Access System
Wiegand Input
(This Device/Reader Must
be Listed to UL 294.)
Data-0
Ground
Data-1
Disconnect power BEFORE making electrical connections.
The CAPXM offers a Wiegand output capable of 26-bit transmission of the
following data:
Success Call with access granted by the resident. The CAPXM will provide a myQ
®
Business™ specified facility code followed by the
Directory Code of the resident that granted access.
And/Or
Successful access through Entry Code. The CAPXM will provide a myQ
®
Business™ specified facility code followed by the
successful Entry Code.
And/Or
Successful access with a Wiegand credential. The CAPXM will pass along the successful credential Facility Code and ID.
INTRODUCTION
PRE-INSTALL
NETWORK
INSTALL
ACCESS CONTROL
Postal Lock
1.
Remove the wing nut and plug. Discard the
wing nut and plug.
2.
Remove 4 mounting nuts from studs.
3.
Install postal lock using 4 nuts.
4.
Cut the factory installed wire tie from the
postal lock switch.
5.
The postal lock switch is wired from the
factory.