LiftMaster CAPXM Installation Manual - English French Spanish Manufactured Pri - Page 15
Connect Power, Wire Specification, Maximum Run Distance
View all LiftMaster CAPXM manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL 4 Connect Power INTRODTUhCe TouIOtleNt for the CPAPRXEM-IMNUSSTTAbLeLan external dedINicaSteTdA1L2L0 Vac outlet. NET•W DOORNKOT use ANAYCpCowEeSr SsuCppOlyNoTthRerOL Refer to the table below for maximum wire run distances. This outlet should than those supplied with your CAPXM. be wired back to its own 10 Amp minimum circuit breaker. • DO NOT power electronic strikes and latches with the same power supply WIRE SPECIFICATION 14 AWG MAXIMUM RUN DISTANCE Up to 300 feet (91.4 m) used to power the access control panel; doing so will cause DAMAGE to the CAPXM. Use ONLY a UL listed burglar INTRODUCTION 16 APWRGE-INSTALL Up toIN2S00TAfeLetL(60.9 m) NETWaplOoawrRmeKroerleacctcroesnsicAcsCotnrCitkrEeosSl saSynsdCtelOmatNcthoTeRs.OL 18 AWG Up to 100 feet (30.4 m) • DO NOT connect the power supply to a switched outlet or otherwise controlled 1. Connect 14-18 AWG wire to the stripped secondary DC output wires on the power supply. Black is negative and red is positive. AC outlet. • DO NOT connect the power supply to the 120 Vac outlet until ALL wiring is 2. Remove the PWR INPUT terminal block from the Control Board. completed. • Install the transient noise suppression 3. Connect the power supply wires to the PWR INPUT terminal block (red device (MOV) supplied with the CAPXM to +24V and black to GND). Reattach the terminal block to the Control for AC powered devices and Diode for Board. DC powered devices. 4. Plug the power supply into a 120 Vac outlet after all connections have been made. • DISCONNECT the power supply from the 120 Vac outlet prior to removing or attaching the terminal block to the NOTE: The green LED on the door board will blink and the green Control Board. LEDs on the Control Board will light solid when powered up. The CAPXM will display the LiftMaster logo while booting up. When boot up is complete, the user interface will appear. 5. Close the CAPXM door. POWER INPUT Control Board Dedicated 10 Amp Minimum Circuit NOTE: If the power supply is installed outdoors, the power supply must have its own approved NEMA 4 Rated weatherproof electrical enclosure. Use conduit from the power supply enclosure to the controller enclosure. Power Supply 15 120 Vac Dedicated Outlet