Epson TM-T88IV TM-T88IV Technical Reference Guide - Page 37

DIP Switch Bank 2, Function, Factory, setting - factory reset

Page 37 highlights

Chapter 2 Setup • The transmission speed can be set with a command or the memory switch utility. (Setting values: 2400, 4800, 9600, 19200, 38400, 57600, 115200) The value set with a command or the memory switch utility is enabled only when DIP switches 1-7 and 1-8 are on. For other settings, the value set with the DIP switches is enabled. • Depending on print conditions such as print duty, print head temperature, and data transmission speed, print speed is automatically adjusted, which can cause white lines due to intermittent print (the motor sometimes stops). To avoid this, set the transmission speed higher or keep the print speed constant by setting it lower. (See "Setting the Memory Switches" on page 43.) DIP Switch Bank 2 SW Function ON OFF Factory setting • Offline 2-1 Handshaking (BUSY condition) Receive buffer full OFF • Receive buffer full Reserved (Do not change 2-2 settings) Fixed to OFF OFF 2 2-3 ∼ S e l e c t s p r i n t d e n s i t y / L ow See "Selecting the Print Density (DIP Switch OFF 2-4 power consumption mode 2-3/2-4)" on page 41. Releases the BUSY Releases the BUSY Setting the release condition state when the state when the of the receive buffer BUSY remaining capacity remaining capacity 2-5 state (This function is effective OFF of the receive of the receive when DIP switch 1-2 is set to buffer reaches 138 buffer reaches 256 off.) bytes. bytes. Reserved (Do not change 2-6 Fixed to OFF OFF settings) 2-7 I/F pin 6 reset signal Enabled Disabled OFF 2-8 IF pin 25 reset signal Enabled Disabled OFF • For DIP switch 2-1 (BUSY condition), see also "Selecting the BUSY Status" on page 42. • Do not change the setting of DIP switches 2-2 and 2-6. Otherwise, the printer may not operate normally. 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

Chapter 2
Setup
37
2
DIP Switch Bank 2
The transmission speed can be set with a command or the memory switch utility.
(Setting values: 2400, 4800, 9600, 19200, 38400, 57600, 115200) The value set with a
command or the memory switch utility is enabled only when DIP switches 1-7 and 1-8
are on. For other settings, the value set with the DIP switches is enabled.
Depending on print conditions such as print duty, print head temperature, and data
transmission speed, print speed is automatically adjusted, which can cause white lines
due to intermittent print (the motor sometimes stops). To avoid this, set the transmission
speed higher or keep the print speed constant by setting it lower. (See
"Setting the
Memory Switches" on page 43
.)
SW
Function
ON
OFF
Factory
setting
2-1
Handshaking (BUSY condition)
Receive buffer full
Offline
Receive buffer full
OFF
2-2
Reserved (Do not change
settings)
Fixed to OFF
OFF
2-3
2-4
Selects print density/Low
power consumption mode
See
"Selecting the Print Density (DIP Switch
2-3/2-4)" on page 41
.
OFF
2-5
Setting the release condition
of the receive buffer BUSY
state (This function is effective
when DIP switch 1-2 is set to
off.)
Releases the BUSY
state when the
remaining capacity
of
the
receive
buffer reaches 138
bytes.
Releases the BUSY
state when the
remaining capacity
of
the
receive
buffer reaches 256
bytes.
OFF
2-6
Reserved (Do not change
settings)
Fixed to OFF
OFF
2-7
I/F pin 6 reset signal
Enabled
Disabled
OFF
2-8
IF pin 25 reset signal
Enabled
Disabled
OFF
For DIP switch 2-1 (BUSY condition), see also
"Selecting the BUSY Status" on page 42
.
Do not change the setting of DIP switches 2-2 and 2-6. Otherwise, the printer may not