Sanyo PLC-ZM5000L RS232C Expand - Page 70
CR_IDSLOT1 Command, 7.16 CR_IDSLOT2 Command, 7.17 CR_IDSLOT3 Command, 7.18 CR_IDSLOT4 Command
UPC - 086483079450
View all Sanyo PLC-ZM5000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command "CR_IDSLOT1" [CR] Details Get ID information of Input1. This command is to determine sources possible to input. Acceptable "000_%1" [CR] Response %1 "32 On-board (HDMI and D-Sub) Available source: DIGITAL, ANALOG, SCART, HDCP, HDMI Unacceptable "Error Code" [CR] 9.7.16 CR_IDSLOT2 Command Command "CR_IDSLOT2" [CR] Details Get ID information of Input2. This command is to determine sources possible to input. Acceptable "000_%1" [CR] Response %1 "41 On-board (5BNC) Available source: ANALOG, VIDEO, YPBPR Unacceptable "Error Code" [CR] 9.7.17 CR_IDSLOT3 Command Command "CR_IDSLOT3" [CR] Details Get ID information of Input3. This command is to determine sources possible to input. Acceptable "000_%1" [CR] Response %1 "51 On-board (3BNC and S-VIDEO) Available source: VIDEO, S-VIDEO, YPBPR Unacceptable "Error Code" [CR] 9.7.18 CR_IDSLOT4 Command Command "CR_IDSLOT4" [CR] Details Get ID information of Input4. This command is to determine sources possible to input. Acceptable "000_%1" [CR] Response "13 PJ-Net (Viewer capable) Available source: Network *With PJ-Net unattached, this command is invalid and error %1 code "103" is returned. *With PJ-Net attached and the power OFF, error code "101" is returned. *In models not supporting PJ-Net, error code "103" is returned. Unacceptable "Error Code" [CR] 70/89