Sanyo PLC-ZM5000L RS232C Expand - Page 61
CR_DDOTS Command, CR_DLINE Command
UPC - 086483079450
View all Sanyo PLC-ZM5000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command "CR_DDOTS" [CR] Details Get value of Display Dots Acceptable "000_%1" [CR] Response %1 Unacceptable "0100 - nnnn" (nnnn = Total Dots - Position H) "Error Code" [CR] ---- When command is not available in the given condition (such as being selected input "?" [CR When unknown command is received 9.5.7 CR_DLINE Command Command "CR_DLINE" [CR] Details Get value of Display Line Acceptable "000_%1" [CR] Response %1 Unacceptable "0100 - nnnn" (nnnn = Total Line - Position V) "Error Code" [CR] ---- When command is not available in the given condition (such as being selected input) "?" [CR When unknown command is received 61/89
PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
61/89
9.5.6
CR_DDOTS Command
Command
“CR_DDOTS” [CR]
Details
Get value of Display Dots
Acceptable
“000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Dots – Position H)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input
“?” [CR] --------------------
When unknown command is received
9.5.7
CR_DLINE Command
Command
“CR_DLINE” [CR]
Details
Get value of Display Line
Acceptable
“000_%1” [CR]
%1
“0100 – nnnn”
(nnnn = Total Line – Position V)
Response
Unacceptable
“Error Code” [CR] ---- When command is not available in the
given condition (such as being selected input)
“?” [CR] --------------------
When unknown command is received